EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices

Ryka M Tashakkor iD, Kian Zamanian iD, Nathan Scott, Safa Farhoumand, Marisela Hernandez, Babak Tashakkor iD

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1736-1740

DOI: 10.1111/pace.70297 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 22.05.2026. Verfasst von Ryka M Tashakkor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Southern California Heart Specialist, Arcadia, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Pacemaker, Artificial, Defibrillators, Implantable, Patient Safety. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) is a critical diagnostic tool known for its non‐invasive nature and high‐resolution imaging capabilities. However, its safety in patients with cardiac implantable electronic devices (CIEDs), particularly those with mixed‐lead systems, remains a significant clinical concern. This report investigates the safety and efficacy of MRI in such patients, where generators and leads originate from different manufacturers and are not officially deemed MRI‐conditional.

Methods

A retrospective, non‐randomized single center study was conducted involving 16 patients with mixed company lead CIEDs that obtained 23 MRIs. All patients underwent clinically indicated 1.5 Tesla MRI scans between July 2021 and August 2025.

Results

Pre‐ and post‐scan measurements included lead impedance, sensing thresholds, and battery voltage, along with monitoring for clinical complications such as arrhythmias, syncope, or cardiac arrest. No adverse effects or device malfunctions were observed, and all key parameters remained stable post‐scan.

Conclusion

This study shows the safe use of MRIs for patients with mixed‐lead CIEDs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPacemaker, ArtificialDefibrillators, ImplantablePatient SafetyHumansRetrospective StudiesFemaleMaleAgedEquipment SafetyMiddle Aged

Stichwörter der Autor:innen

cardiac implantable electronic devicesleadsmagnetic resonance imagingpacemakersafety

Autor:innen und Institutionen

  • Southern California Heart Specialist, Arcadia, California, USA.
  • Abbott, Sylmar, California, USA.
  • University of Southern California, Arcadia, California, USA.

ORCID-Profile: Ryka M Tashakkor, Kian Zamanian, Babak Tashakkor

Zitieren

APA

Tashakkor, R. M., Zamanian, K., Scott, N., Farhoumand, S., Hernandez, M., & Tashakkor, B. (2026). Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices. Pacing and Clinical Electrophysiology, 49(11), 1736-1740. https://doi.org/10.1111/pace.70297

Vancouver

Tashakkor RM, Zamanian K, Scott N, Farhoumand S, Hernandez M, Tashakkor B. Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices. Pacing and Clinical Electrophysiology. 2026;49(11):1736-1740. doi:10.1111/pace.70297

BibTeX
@article{Tashakkor2026,
  author = {Tashakkor, Ryka M and Zamanian, Kian and Scott, Nathan and Farhoumand, Safa and Hernandez, Marisela and Tashakkor, Babak},
  title = {Magnetic Resonance Imaging Safety in Patients With Conditional Mixed‐Manufacturer Devices},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {11},
  pages = {1736--1740},
  doi = {10.1111/pace.70297}
}
Kostenlos starten →