EUVIMEDSkopri EUVIMED
ÜbersichtsarbeitOpen access

How to Use a Variable Loop Circular Catheter to Perform Zero Fluoro Pulmonary Vein Isolation With Pulsed Field Ablation

William K Chan iD, Melani Keshishi, Tara Gomez, Umjeet S Jolly

Pacing and Clinical Electrophysiology · 2026

DOI: 10.1111/pace.70244 ↗

At a glance

Übersichtsarbeit in Pacing and Clinical Electrophysiology, 2026. Written by William K Chan and 3 co-authors. Institution: Heart Rhythm Program, Waterloo Regional Health Network, Kitchener, Ontario, Canada. Major MEDLINE topics: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation. Cited 1 times so far (Crossref); 20 references. The full text is freely available in PubMed Central.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

The variable loop circular catheter (VLCC) called VARIPULSE is a novel device designed for catheter ablation of atrial fibrillation (AFib) and electro‐anatomical mapping via 3D intracardiac echocardiography (ICE). Described herein is a streamlined workflow for AFib ablation and reported feasibility, procedural efficiency, and early safety signals of the first 34 consecutive patients. The technical details of step‐by‐step techniques are described to serve as a practical guide for clinicians and investigators.

Methods

A retrospective, single‐center review of procedural parameters was done on 34 paroxysmal and/or persistent AFib patients who were treated with a VLCC for both mapping and ablating between January 1, 2025 and May 15, 2025. The workflow of all procedures was comprised of general anesthesia administration, placement of 2 sheaths via ultrasound guided access, administration of a heparin bolus, 3D anatomical mapping of the pulmonary veins with CARTOSOUND FAM, a transeptal puncture, VLCC ablation, and then closure. Figures illustrating key procedural steps, including catheter maneuvering, are included.

Results

All 34 cases were done without fluoroscopy, with a median procedural time of 40.5 [IQR 19] min. After 10 procedures per operator, consistently shorter procedure times (

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationPulmonary VeinsCatheter AblationHumansRetrospective StudiesFemaleMaleIrreversible Electroporation TherapyMiddle AgedEquipment DesignFluoroscopyAgedEchocardiography, Three-DimensionalUltrasonography, Interventional

Author keywords

atrial fibrillationintracardiac echocardiogramirreversible electroporationparoxysmal atrial fibrillationpersistent atrial fibrillationpulmonary vein isolationpulsed field ablationzero fluoroscopy

Authors and institutions

  • Heart Rhythm Program, Waterloo Regional Health Network, Kitchener, Ontario, Canada.
  • Department of Medicine, McMaster University, Hamilton, Ontario, Canada.
  • Johnson & Johnson, MedTech, 31 Technology Dr Suite, Irvine, California, USA.

ORCID profiles: William K Chan

Cite

APA

Chan, W. K., Keshishi, M., Gomez, T., & Jolly, U. S. (2026). How to Use a Variable Loop Circular Catheter to Perform Zero Fluoro Pulmonary Vein Isolation With Pulsed Field Ablation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70244

Vancouver

Chan WK, Keshishi M, Gomez T, Jolly US. How to Use a Variable Loop Circular Catheter to Perform Zero Fluoro Pulmonary Vein Isolation With Pulsed Field Ablation. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70244

BibTeX
@article{Chan2026,
  author = {Chan, William K and Keshishi, Melani and Gomez, Tara and Jolly, Umjeet S},
  title = {How to Use a Variable Loop Circular Catheter to Perform Zero Fluoro Pulmonary Vein Isolation With Pulsed Field Ablation},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70244}
}