EUVIMEDEUVIMED entdecken
Crossref

Real‐World Experience With the Balloon‐in‐Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra‐Pulmonary Vein Sites

Henri Xhakupi iD, Tommaso Sattin, Domenico G Della Rocca iD, Ludovica Carmagnola, Domenico Laviola iD, Paul-Adrian Calburean, Luca Canovi iD, Francesca Salghetti iD, Giampaolo Vetta, Alvise Del Monte iD, Charles Audiat iD, Antonio Sorgente und 9 weitere

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70509 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Henri Xhakupi und 20 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology an…. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A novel balloon‐in‐basket pulsed field ablation (PFA) system integrated with electroanatomical mapping has recently been introduced. However, real‐world data on this technology, particularly for adjunctive posterior wall isolation (PWI) and extra‐pulmonary vein sites, remain limited.

Objective

To evaluate the acute performance, safety, and feasibility of pulmonary vein isolation (PVI) and adjunctive lesions using a balloon‐in‐basket PFA system.

Methods

Consecutive patients with symptomatic paroxysmal or persistent AF undergoing ablation with the balloon‐in‐basket PFA system between February 2024 and February 2026 were included. Acute efficacy, procedural parameters, complications, exploratory haemolysis and renal biomarkers, and follow‐up outcomes were assessed.

Results

A total of 133 patients were included; 94 (70.7%) had paroxysmal AF and 39 (29.3%) persistent AF. Acute PVI was achieved in 96.2% of cases. Adjunctive PWI was performed in 25.6% of patients, and additional extra‐PV lesion sets were performed in 12 patients. Mean procedure, left atrial dwelling, and fluoroscopy times were 65.6 ± 16.4, 45.4 ± 15.4, and 12.7 ± 7.3 min, respectively, with no significant differences between PVI‐only and PVI + PWI procedures. Two periprocedural complications occurred (1.5%; femoral arterial pseudoaneurysm, pericarditis). Exploratory biomarker analyses showed no evident haemolysis‐related renal safety signal. Among 82 patients with ≥ 6 months of follow‐up, late clinically documented atrial arrhythmia recurrence occurred in 14.6%.

Conclusion

In this real‐world experience, the balloon‐in‐basket PFA system showed high acute efficacy, low complication rates, and efficient workflow. Adjunctive PWI appeared feasible in selected patients, with exploratory comparisons showing no evident increase in procedural burden or additional biomarker safety signal.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsAtrial FibrillationCatheter AblationHumansFemaleMiddle AgedTreatment OutcomeMaleTime FactorsAgedFeasibility StudiesIrreversible Electroporation TherapyHeart RateAction PotentialsRecurrenceRisk FactorsEquipment DesignRetrospective Studies

Stichwörter der Autor:innen

atrial fibrillationposterior wall isolationpulmonary vein isolationpulsed field ablationreal‐world outcomes

Autor:innen und Institutionen

  • Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guar…
  • Department of Internal Medicine, University of Genoa, Genova, Italy.

ORCID-Profile: Henri Xhakupi, Domenico G Della Rocca, Domenico Laviola, Luca Canovi, Francesca Salghetti, Alvise Del Monte, Charles Audiat, Ingrid Overeinder, Ivan Eltsov, Carlo de Asmundis

Zitieren

APA

Xhakupi, H., Sattin, T., Della Rocca, D. G., Carmagnola, L., Laviola, D., Calburean, P. A., Canovi, L., Salghetti, F., Vetta, G., Monte, A. D., Audiat, C., Sorgente, A., Bala, G., Pannone, L., Overeinder, I., Eltsov, I., Sieira, J., Stroker, E., Sarkozy, A., …, & Chierchia, G. B. (2026). Real‐World Experience With the Balloon‐in‐Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra‐Pulmonary Vein Sites. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70509

Vancouver

Xhakupi H, Sattin T, Della Rocca DG, Carmagnola L, Laviola D, Calburean PA, et al. Real‐World Experience With the Balloon‐in‐Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra‐Pulmonary Vein Sites. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70509

BibTeX
@article{Xhakupi2026,
  author = {Xhakupi, Henri and Sattin, Tommaso and Della Rocca, Domenico G and Carmagnola, Ludovica and Laviola, Domenico and Calburean, Paul-Adrian and Canovi, Luca and Salghetti, Francesca and Vetta, Giampaolo and Monte, Alvise Del and Audiat, Charles and Sorgente, Antonio and Bala, Gezim and Pannone, Luigi and Overeinder, Ingrid and Eltsov, Ivan and Sieira, Juan and Stroker, Erwin and Sarkozy, Andrea and de Asmundis, Carlo and Chierchia, Gian-Battista},
  title = {Real‐World Experience With the Balloon‐in‐Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra‐Pulmonary Vein Sites},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70509}
}
Kostenlos starten →