Systematische Übersicht in Pacing and Clinical Electrophysiology, published online on 2026-04-12. Written by Qing Jin and 2 co-authors. Institution: Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan…. Major MEDLINE topics: Cardiomyopathies, Cardiac Resynchronization Therapy, Heart Conduction System, Cardiac Pacing, Artificial. Cited 3 times so far (Crossref); 34 references. Funded by: Shandong Province Medical Staff Scientific and Technological Innovation Plan Project.

ΠερίληψηSubjectsΒιβλιογραφικά στοιχείαCiteRelated studies

Abstract (original language)

Background

Biventricular pacing (BVP) and conduction system pacing (CSP) can enhance pacing‐induced cardiomyopathy (PICM) patients' clinical outcomes. Although BVP is a class I recommendation in guidelines, CSP may provide a superior physiological alternative to BVP. This meta‐analysis compares the efficacy and safety of CSP and BVP in PICM patients.

Methods

Databases including PubMed, Cochrane Library, Web of Science, and Embase were searched from their establishment to June 2025. Data analysis was performed using Stata 17.

Results

Twenty observational studies involving 821 patients with PICM were included, among which 360 patients were treated with BVP and 461 patients with CSP. Results showed CSP had a greater QRS duration (QRSd) reduction than BVP (MD = −53.26 ms, 95% CI: −58.13, −48.39 vs. MD = −30.69 ms, 95% CI: −35.79, −25.59) ( p < 0.001). After 15.6 months' follow‐up, CSP had a higher response rate (84.7% vs. 67.6%) (RR = 1.25, 95% CI: 1.14, 1.38) ( p < 0.001) and lower incidences of adverse outcomes and device‐related complications (14.0% vs. 20.1%) (RR = 0.7, 95% CI: 0.5, 0.98) ( p < 0.001) than BVP. Subgroup analysis showed His bundle pacing (HBP) was associated with greater QRSd shortening, while left bundle branch area pacing (LBBAP) had lower thresholds.

Conclusions

The results indicate that upgrading to CSP in PICM patients significantly improves electrical synchrony, and correlates with higher response rates and lower adverse outcomes, suggesting CSP as a promising alternative pacing strategy.

Subjects

MeSH terms (MEDLINE)

CardiomyopathiesCardiac Resynchronization TherapyHeart Conduction SystemCardiac Pacing, ArtificialHumans

Author keywords

His bundle pacingbiventricular pacingconduction system pacingleft bundle branch area pacingpacing‐induced cardiomyopathy

Authors and institutions

  • Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
  • Department of Medical Ultrasound, Jining Medical University, Jining, China.

ORCID profiles: Qing Jin, Haiyan Wang

Funding

  • Shandong Province Medical Staff Scientific and Technological Innovation Plan Project

Cite

APA

Jin, Q., Ren, X., & Wang, H. (2026). Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology, 49(7), 851-866. https://doi.org/10.1111/pace.70243

Vancouver

Jin Q, Ren X, Wang H. Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology. 2026;49(7):851-866. doi:10.1111/pace.70243

BibTeX
@article{Jin2026,
  author = {Jin, Qing and Ren, Xingbiao and Wang, Haiyan},
  title = {Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  volume = {49},
  number = {7},
  pages = {851--866},
  doi = {10.1111/pace.70243}
}
Start for free →