Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis
Pacing and Clinical Electrophysiology · 2026-07 · 49 (7) · 851-866
DOI: 10.1111/pace.70243 ↗At a glance
Systematische Übersicht in Pacing and Clinical Electrophysiology, published online on 2026-04-12. Written by Qing Jin and 2 co-authors. Institution: Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan…. Major MEDLINE topics: Cardiomyopathies, Cardiac Resynchronization Therapy, Heart Conduction System, Cardiac Pacing, Artificial. Cited 3 times so far (Crossref); 34 references. Funded by: Shandong Province Medical Staff Scientific and Technological Innovation Plan Project.
Abstract (original language)
Background
Biventricular pacing (BVP) and conduction system pacing (CSP) can enhance pacing‐induced cardiomyopathy (PICM) patients' clinical outcomes. Although BVP is a class I recommendation in guidelines, CSP may provide a superior physiological alternative to BVP. This meta‐analysis compares the efficacy and safety of CSP and BVP in PICM patients.
Methods
Databases including PubMed, Cochrane Library, Web of Science, and Embase were searched from their establishment to June 2025. Data analysis was performed using Stata 17.
Results
Twenty observational studies involving 821 patients with PICM were included, among which 360 patients were treated with BVP and 461 patients with CSP. Results showed CSP had a greater QRS duration (QRSd) reduction than BVP (MD = −53.26 ms, 95% CI: −58.13, −48.39 vs. MD = −30.69 ms, 95% CI: −35.79, −25.59) ( p < 0.001). After 15.6 months' follow‐up, CSP had a higher response rate (84.7% vs. 67.6%) (RR = 1.25, 95% CI: 1.14, 1.38) ( p < 0.001) and lower incidences of adverse outcomes and device‐related complications (14.0% vs. 20.1%) (RR = 0.7, 95% CI: 0.5, 0.98) ( p < 0.001) than BVP. Subgroup analysis showed His bundle pacing (HBP) was associated with greater QRSd shortening, while left bundle branch area pacing (LBBAP) had lower thresholds.
Conclusions
The results indicate that upgrading to CSP in PICM patients significantly improves electrical synchrony, and correlates with higher response rates and lower adverse outcomes, suggesting CSP as a promising alternative pacing strategy.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
- Department of Medical Ultrasound, Jining Medical University, Jining, China.
ORCID profiles: Qing Jin, Haiyan Wang
Funding
- Shandong Province Medical Staff Scientific and Technological Innovation Plan Project
Cite
APA
Jin, Q., Ren, X., & Wang, H. (2026). Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology, 49(7), 851-866. https://doi.org/10.1111/pace.70243
Vancouver
Jin Q, Ren X, Wang H. Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology. 2026;49(7):851-866. doi:10.1111/pace.70243
BibTeX
@article{Jin2026,
author = {Jin, Qing and Ren, Xingbiao and Wang, Haiyan},
title = {Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
volume = {49},
number = {7},
pages = {851--866},
doi = {10.1111/pace.70243}
}