Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis
Pacing and Clinical Electrophysiology · 2026-07 · 49 (7) · 851-866
DOI: 10.1111/pace.70243 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 12.04.2026. Verfasst von Qing Jin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan…. Hauptthemen laut MEDLINE: Cardiomyopathies, Cardiac Resynchronization Therapy, Heart Conduction System, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Shandong Province Medical Staff Scientific and Technological Innovation Plan Project.
Abstract (Originalsprache)
Background
Biventricular pacing (BVP) and conduction system pacing (CSP) can enhance pacing‐induced cardiomyopathy (PICM) patients' clinical outcomes. Although BVP is a class I recommendation in guidelines, CSP may provide a superior physiological alternative to BVP. This meta‐analysis compares the efficacy and safety of CSP and BVP in PICM patients.
Methods
Databases including PubMed, Cochrane Library, Web of Science, and Embase were searched from their establishment to June 2025. Data analysis was performed using Stata 17.
Results
Twenty observational studies involving 821 patients with PICM were included, among which 360 patients were treated with BVP and 461 patients with CSP. Results showed CSP had a greater QRS duration (QRSd) reduction than BVP (MD = −53.26 ms, 95% CI: −58.13, −48.39 vs. MD = −30.69 ms, 95% CI: −35.79, −25.59) ( p < 0.001). After 15.6 months' follow‐up, CSP had a higher response rate (84.7% vs. 67.6%) (RR = 1.25, 95% CI: 1.14, 1.38) ( p < 0.001) and lower incidences of adverse outcomes and device‐related complications (14.0% vs. 20.1%) (RR = 0.7, 95% CI: 0.5, 0.98) ( p < 0.001) than BVP. Subgroup analysis showed His bundle pacing (HBP) was associated with greater QRSd shortening, while left bundle branch area pacing (LBBAP) had lower thresholds.
Conclusions
The results indicate that upgrading to CSP in PICM patients significantly improves electrical synchrony, and correlates with higher response rates and lower adverse outcomes, suggesting CSP as a promising alternative pacing strategy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
- Department of Medical Ultrasound, Jining Medical University, Jining, China.
ORCID-Profile: Qing Jin, Haiyan Wang
Förderung
- Shandong Province Medical Staff Scientific and Technological Innovation Plan Project
Zitieren
APA
Jin, Q., Ren, X., & Wang, H. (2026). Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology, 49(7), 851-866. https://doi.org/10.1111/pace.70243
Vancouver
Jin Q, Ren X, Wang H. Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis. Pacing and Clinical Electrophysiology. 2026;49(7):851-866. doi:10.1111/pace.70243
BibTeX
@article{Jin2026,
author = {Jin, Qing and Ren, Xingbiao and Wang, Haiyan},
title = {Conduction System Versus Biventricular Pacing in Pacing‐Induced Cardiomyopathy: Systematic Review and Meta‐Analysis},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
volume = {49},
number = {7},
pages = {851--866},
doi = {10.1111/pace.70243}
}
EUVIMED