Optimization of Cryoablation Catheter–Tissue Contact Using the Contact Index
Pacing and Clinical Electrophysiology · 2026
DOI: 10.1111/pace.70235 ↗At a glance
Fallbericht in Pacing and Clinical Electrophysiology, 2026. Written by Kentaro Hayashi and 9 co-authors. Institution: Department of Cardiology, Arrhythmia Center, Ageo Central General Hospital, Ageo City, Saitama, Japan. Major MEDLINE topics: Cardiac Catheters, Cryosurgery, Surgery, Computer-Assisted, Tachycardia, Supraventricular. 5 references. The full text is freely available in PubMed Central.
Abstract (original language)
Introduction
Cryoablation is widely used for septal paroxysmal supraventricular tachycardia because of its lower risk of atrioventricular block; however, real‐time quantitative assessment of catheter–tissue contact is limited. Methods and Results We describe a modified configuration enabling visualization of the contact index (CI) during cryoablation with the Freezor Xtra catheter, supported by in vitro validation and two clinical cases. In vitro testing demonstrated progressive CI elevation with decreasing catheter–tissue distance. Successful lesions were achieved at CI values of approximately 20%–25%. CI increased despite minimal electrogram changes and correlated with tissue proximity.
Conclusion
CI‐guided cryoablation is feasible and may improve contact assessment during septal ablation.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Arrhythmia Center, Ageo Central General Hospital, Ageo City, Saitama, Japan.
- Department of Clinical Engineering, Ageo Central General Hospital, Ageo City, Saitama, Japan.
- Department of Cardiology, Ageo Central General Hospital, Ageo City, Saitama, Japan.
ORCID profiles: Takeshi Kitamura
Cite
APA
Hayashi, K., Kitamura, T., Izumi, C., Nagahara, M., Sahashi, S., Lee, K., Sugiyama, H., Tanimoto, S., Ogata, N., & Isshiki, T. (2026). Optimization of Cryoablation Catheter–Tissue Contact Using the Contact Index. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70235
Vancouver
Hayashi K, Kitamura T, Izumi C, Nagahara M, Sahashi S, Lee K, et al. Optimization of Cryoablation Catheter–Tissue Contact Using the Contact Index. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70235
BibTeX
@article{Hayashi2026,
author = {Hayashi, Kentaro and Kitamura, Takeshi and Izumi, Chihiro and Nagahara, Masashi and Sahashi, Shuichi and Lee, Kyonghee and Sugiyama, Haruki and Tanimoto, Shuzo and Ogata, Nobuhiko and Isshiki, Takaaki},
title = {Optimization of Cryoablation Catheter–Tissue Contact Using the Contact Index},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70235}
}
EUVIMED