EUVIMEDEUVIMED entdecken
Crossref

Distribution of antral lesions with the novel size‐adjustable cryoballoon for pulmonary vein isolation and the differences based on left atrial remodeling

Kentaro Goto iD, Shinsuke Miyazaki, Miho Negishi, Takashi Ikenouchi, Tasuku Yamamoto, Iwanari Kawamura, Takuro Nishimura, Tomomasa Takamiya, Susumu Tao, Masateru Takigawa iD, Tetsuo Sasano iD

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16415 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Kentaro Goto und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Cryosurgery, Atrial Remodeling. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The novel cryoballoon with 28 mm or 31 mm adjustable diameters, aims to achieve a wide antral pulmonary vein isolation (PVI). However, the distribution of antral lesions and their variations based on left atrial (LA) remodeling require further clarification.

Methods

We evaluated 22 patients (67 [59.5–74.8] years, 19 males) who underwent PVI of atrial fibrillation (AF) (13 paroxysmal AF [PAF] and 9 non‐PAF) using size‐adjustable cryoballoons. LA electro‐anatomical mapping was performed post‐PVI with three‐dimensional mapping systems. We assessed the shapes of the LA and pulmonary veins (PVs) and the distribution of isolated areas (IAs), comparing the results between PAF and non‐PAF patients.

Results

In the left PVs (LPVs), the distance between the PV orifice and IA edge (PVos‐IA) was larger on the roof and posterior segments (~15 mm) but relatively smaller on the anterior segment near the PV ridge (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsAtrial FibrillationCryosurgeryAtrial RemodelingHumansMaleFemaleMiddle AgedAgedTreatment OutcomeEquipment DesignAction PotentialsElectrophysiologic Techniques, CardiacHeart AtriaCardiac Catheters

Stichwörter der Autor:innen

atrial fibrillationsize‐adjustable cryoballoonthree‐dimensional mapping

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan.

ORCID-Profile: Kentaro Goto, Masateru Takigawa, Tetsuo Sasano

Zitieren

APA

Goto, K., Miyazaki, S., Negishi, M., Ikenouchi, T., Yamamoto, T., Kawamura, I., Nishimura, T., Takamiya, T., Tao, S., Takigawa, M., & Sasano, T. (2024). Distribution of antral lesions with the novel size‐adjustable cryoballoon for pulmonary vein isolation and the differences based on left atrial remodeling. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16415

Vancouver

Goto K, Miyazaki S, Negishi M, Ikenouchi T, Yamamoto T, Kawamura I, et al. Distribution of antral lesions with the novel size‐adjustable cryoballoon for pulmonary vein isolation and the differences based on left atrial remodeling. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16415

BibTeX
@article{Goto2024,
  author = {Goto, Kentaro and Miyazaki, Shinsuke and Negishi, Miho and Ikenouchi, Takashi and Yamamoto, Tasuku and Kawamura, Iwanari and Nishimura, Takuro and Takamiya, Tomomasa and Tao, Susumu and Takigawa, Masateru and Sasano, Tetsuo},
  title = {Distribution of antral lesions with the novel size‐adjustable cryoballoon for pulmonary vein isolation and the differences based on left atrial remodeling},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16415}
}
Kostenlos starten →