EUVIMEDObjevte EUVIMED
KohortenstudieOpen access

Apical Lead Position Increases the Risk of Right Ventricular Lead Perforation: A Retrospective Cohort Study

Yuji Manabe iD, Tabito Kino, Shunichi Asano, Tomoyuki Fukuzawa, Shingo Tanaka, Jun Osada, Shinya Kowase iD, Hajime Aoki, Kazuhiko Yumoto

Pacing and Clinical Electrophysiology · 2026

DOI: 10.1111/pace.70231 ↗

At a glance

Kohortenstudie in Pacing and Clinical Electrophysiology, 2026. Written by Yuji Manabe and 8 co-authors. Institution: Department of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan. Major MEDLINE topics: Defibrillators, Implantable, Heart Ventricles, Electrodes, Implanted, Pacemaker, Artificial. 17 references. The full text is freely available in PubMed Central.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Right ventricular (RV) lead perforation is a rare but potentially life‐threatening complication of cardiac implantable electronic devices. Although apical lead placement has been proposed as a risk factor, its clinical significance remains uncertain. This study evaluated whether apical RV lead positioning increases perforation risk and characterized the clinical features, diagnosis, and outcomes of affected patients.

Methods

We retrospectively reviewed data from 1,923 patients who underwent RV lead implantation between January 2002 and June 2023. Patients were categorized into Apex and Non‐apex groups according to lead tip location. RV lead perforation cases were identified based on chest radiography findings. Baseline characteristics and the incidence and management of lead perforation were analyzed.

Results

Among the 1,923 patients, 503 (26.2%) were assigned to the Apex group and 1,420 (73.8%) to the Non‐apex group. RV lead perforation occurred in 5 patients (0.26%): 4 in the Apex group and 1 in the Non‐apex group (0.79% vs. 0.07%, p = 0.018). Perforations were diagnosed intraoperatively or within 1–3 days post‐implantation, primarily using chest computed tomography. Clinical presentations ranged from asymptomatic findings to chest pain. All patients underwent percutaneous RV lead extraction and revision, without major complications.

Conclusion

Apical RV lead positioning was significantly associated with an increased risk of lead perforation. Although perforation was uncommon, prompt diagnosis and individualized management ensured favorable outcomes. Careful attention to lead tip location during implantation may help mitigate this risk. Given the small number of events, this finding should be interpreted as hypothesis‐generating.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantableHeart VentriclesElectrodes, ImplantedPacemaker, ArtificialHeart InjuriesHumansRetrospective StudiesFemaleMaleAgedRisk FactorsMiddle AgedDevice Lead Extraction

Author keywords

cardiac implantable electronic deviceslead positionpercutaneous lead extractionright ventricular lead perforation

Authors and institutions

  • Department of Cardiology, Yokohama Rosai Hospital, Yokohama, Japan.

ORCID profiles: Yuji Manabe, Shinya Kowase

Cite

APA

Manabe, Y., Kino, T., Asano, S., Fukuzawa, T., Tanaka, S., Osada, J., Kowase, S., Aoki, H., & Yumoto, K. (2026). Apical Lead Position Increases the Risk of Right Ventricular Lead Perforation: A Retrospective Cohort Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70231

Vancouver

Manabe Y, Kino T, Asano S, Fukuzawa T, Tanaka S, Osada J, et al. Apical Lead Position Increases the Risk of Right Ventricular Lead Perforation: A Retrospective Cohort Study. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70231

BibTeX
@article{Manabe2026,
  author = {Manabe, Yuji and Kino, Tabito and Asano, Shunichi and Fukuzawa, Tomoyuki and Tanaka, Shingo and Osada, Jun and Kowase, Shinya and Aoki, Hajime and Yumoto, Kazuhiko},
  title = {Apical Lead Position Increases the Risk of Right Ventricular Lead Perforation: A Retrospective Cohort Study},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70231}
}
Start for free →