EUVIMEDEUVIMED entdecken
Multizentrische Studie

Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions

Tatyana Storozhenko, Giulio Russo, Marc Vanderheyden, Ole De Backer, Michael Rosseel, Hadewich Hermans, Philippe Vanduynhoven, Tom De Potter, Guy Van Camp, Marianna Adamo, Edoardo Pancaldi, Rodrigo Estevez-Loureiro und 15 weitere

JACC: Clinical Electrophysiology · 2026-03 · 12 (3) · 489-497

DOI: 10.1016/j.jacep.2025.11.003 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2026-03. Verfasst von Tatyana Storozhenko und 26 weiteren Autor:innen. Beteiligte Einrichtung: Hartcentrum Aalst, AZORG, Aalst, Belgium; Department of Prevention and Treatment of Emergency Conditions, L.T. Malaya Therapy National Institute NAMS…. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Pacemaker, Artificial, Heart Ventricles, Tricuspid Valve. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Tricuspid transcatheter edge-to-edge repair (T-TEER) is an important treatment option for symptomatic severe tricuspid valve regurgitation. Interaction with a preexisting right ventricular (RV) pacing lead can result in clinically significant RV lead dysfunction over time. OBJECTIVES: The goal of this study was to evaluate the 2-year safety and function of preexisting RV leads after T-TEER. METHODS: The Tri-LEAD (Tricuspid Right Ventricular lead entrapment in transcatheter tricuspid interventions) study was a retrospective multicenter international registry of 146 patients who underwent T-TEER with an RV lead in situ from 2015 to 2023. Primary outcome was RV lead dysfunction after T-TEER at 2 years (defined as change in RV lead function, dislodgement, or fracture) and need for intervention due to RV lead dysfunction or cardiac complication. RESULTS: Mean patient age was 78.1 ± 8.6 years, and 54% were male. Over a median follow-up of 557 days (Q1-Q3: 278-966 days), 10 patients (6.8%) had an impedance change >200 Ω and 2 patients (1.4%) had a threshold change ≥1 V, with no observed cases of RV lead fracture, dislodgement, cardiac structure perforation, or pacemaker-related re-interventions. T-TEER was not associated with an increased risk of the composite safety endpoint (adjusted SHR: 1.39; 95% CI: 0.64 to 3.02; P = 0.41). Over time, changes in RV lead sensing (-0.53 mV/year; 95% CI: -1.15 to 0.08; P = 0.094), impedance (-2.4 Ω/year; 95% CI: -15.4 to 10.6; P = 0.72), and threshold (-0.011 V/year; 95% CI: -0.052 to 0.031; P = 0.62) were minimal and not clinically significant. CONCLUSIONS: T-TEER has no detrimental impact on the performance of transvenous RV leads in the short term or midterm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tricuspid Valve InsufficiencyPacemaker, ArtificialHeart VentriclesTricuspid ValveCardiac CatheterizationHumansRetrospective StudiesMaleAgedFemaleAged, 80 and overElectrodes, ImplantedEquipment Failure

Stichwörter der Autor:innen

RV lead entrapmentdefibrillator leadpacemaker leadtranscatheter tricuspid valve interventiontricuspid edge-to-edge repairtricuspid regurgitation

Autor:innen und Institutionen

  • Hartcentrum Aalst, AZORG, Aalst, Belgium; Department of Prevention and Treatment of Emergency Conditions, L.T. Malaya Therapy National Institute NAMSU, Kharkiv, Ukraine.
  • Department of Biomedicine and Prevention, Cardiology Unit, Policlinico Tor Vergata, University of Rome, Rome, Italy.
  • Hartcentrum Aalst, AZORG, Aalst, Belgium.
  • The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
  • Cardiac Catheterization Laboratory and Cardiology, ASST Spedali Civili and Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.
  • Hospital Alvaro Cunqueiro, Department of Interventional Cardiology, Vigo, Pontevedra, Spain.

Zitieren

APA

Storozhenko, T., Russo, G., Vanderheyden, M., De Backer, O., Rosseel, M., Hermans, H., Vanduynhoven, P., De Potter, T., Van Camp, G., Adamo, M., Pancaldi, E., Estevez-Loureiro, R., Sievert, H., Piayda, K., Mylotte, D., Lochy, S., Hausleiter, J., Stolz, L., Nestelberger, T., …, & Rosseel, L. (2026). Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions. JACC: Clinical Electrophysiology, 12(3), 489-497. https://doi.org/10.1016/j.jacep.2025.11.003

Vancouver

Storozhenko T, Russo G, Vanderheyden M, De Backer O, Rosseel M, Hermans H, et al. Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions. JACC: Clinical Electrophysiology. 2026;12(3):489-497. doi:10.1016/j.jacep.2025.11.003

BibTeX
@article{Storozhenko2026,
  author = {Storozhenko, Tatyana and Russo, Giulio and Vanderheyden, Marc and De Backer, Ole and Rosseel, Michael and Hermans, Hadewich and Vanduynhoven, Philippe and De Potter, Tom and Van Camp, Guy and Adamo, Marianna and Pancaldi, Edoardo and Estevez-Loureiro, Rodrigo and Sievert, Horst and Piayda, Kerstin and Mylotte, Darren and Lochy, Stijn and Hausleiter, Joerg and Stolz, Lukas and Nestelberger, Thomas and Wagener, Max and Patterson, Tiffany and Wilcox, Joshua and Swaans, Martin J and Timmers, Leo and Vrijkorte, Martijn and Taramasso, Maurizio and Rosseel, Liesbeth},
  title = {Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions},
  journal = {JACC: Clinical Electrophysiology},
  year = {2026},
  volume = {12},
  number = {3},
  pages = {489--497},
  doi = {10.1016/j.jacep.2025.11.003}
}
Kostenlos starten →