Computed tomography predictors of increased transvenous lead extraction difficulty
Pacing and Clinical Electrophysiology · 2024-09 · 47 (9) · 1232-1240
DOI: 10.1111/pace.15034 ↗At a glance
Journal article in Pacing and Clinical Electrophysiology, published online on 2024-07-05. Written by Kavisha Patel and 7 co-authors. Institution: Department of Cardiology, University of California San Diego, La Jolla, California, USA. Major MEDLINE topics: Device Removal, Tomography, X-Ray Computed, Defibrillators, Implantable. Cited 4 times so far (Crossref); 28 references.
Abstract (original language)
Background
The ability of computed tomography (CT) characteristics to predict the difficulty of transvenous lead extraction (TLE) is an evolving subject.
Objective
To identify CT characteristics associated with increased TLE difficulty.
Methods
All consecutive patients undergoing TLE at the University of California San Diego from January 2018 to February 2022 were analyzed, utilizing the UC San Diego Lead Extraction Registry. Patients underwent cardiac‐gated chest CT scans with intravenous contrast; all scans were reviewed by a single radiologist. Lead extraction was performed per standard institutional protocol with the initial use of a laser sheath and crossover to a mechanical sheath as needed. Multivariable linear and logistic regression analyses were performed to identify predictors of individual lead‐removal fluoroscopy time and mechanical sheath use, as markers of extraction difficulty.
Results
A total of 343 patients were analyzed. The mean age of the study population was 63.8 ± 15.4 years; 71% were male. The mean lead dwell‐in duration was 8.6 ± 5.7 years. In multivariable linear regression analysis, venous occlusion detected on CT was independently associated with higher individual lead‐removal fluoroscopy time ( p = 0.004), when adjusting for clinical characteristics such as lead dwell time. In multivariable logistic regression analysis, calcification and venous occlusion were independently associated with a higher need for mechanical sheath use during TLE (odds ratio:5.08, p < 0.001, 95% CI: 2.54–10.46) and (odds ratio:3.72, p < 0.001, 95% CI: 1.89–7.35), respectively.
Conclusion
In patients undergoing TLE, venous occlusion identified by chest CT is associated with increased fluoroscopy time. Patients with lead‐associated calcification or venous occlusion detected by chest CT are each five and three times more likely to require crossover from laser to a mechanical sheath.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, University of California San Diego, La Jolla, California, USA.
- Department of Cardiology, Kansas City Heart Rhythm Institute, Kansas City, Kansas, USA.
ORCID profiles: Kavisha Patel, Douglas Darden
Cite
APA
Patel, K., Toomu, S., Lee, E., Darden, D., Jacobs, K., Pollema, T., Ho, G., & Birgersdotter-Green, U. (2024). Computed tomography predictors of increased transvenous lead extraction difficulty. Pacing and Clinical Electrophysiology, 47(9), 1232-1240. https://doi.org/10.1111/pace.15034
Vancouver
Patel K, Toomu S, Lee E, Darden D, Jacobs K, Pollema T, et al. Computed tomography predictors of increased transvenous lead extraction difficulty. Pacing and Clinical Electrophysiology. 2024;47(9):1232-1240. doi:10.1111/pace.15034
BibTeX
@article{Patel2024,
author = {Patel, Kavisha and Toomu, Sandeep and Lee, Euyhyun and Darden, Douglas and Jacobs, Kathleen and Pollema, Travis and Ho, Gordon and Birgersdotter-Green, Ulrika},
title = {Computed tomography predictors of increased transvenous lead extraction difficulty},
journal = {Pacing and Clinical Electrophysiology},
year = {2024},
volume = {47},
number = {9},
pages = {1232--1240},
doi = {10.1111/pace.15034}
}
EUVIMED