EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pre-procedural computed tomography predicts procedural complexity and complications in bidirectional rotational mechanical transvenous lead extraction

Federico Migliore iD, Raimondo Pittorru iD, Vincenzo Tarzia, Jacopo Rosso, Manuel De Lazzari iD, Andrea Ziggiotto, Gaia Zancanaro, Giulia Winnicki iD, Marco Gemelli iD, Matteo Micciolo, Antonio Guerrieri, Davide Margheri iD und 4 weitere

Europace · 01.12.2025 · 27 (12)

DOI: 10.1093/europace/euaf308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 06.12.2025. Verfasst von Federico Migliore und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via N. Giustiniani 2, Padua 35121, Italy. Hauptthemen laut MEDLINE: Device Removal, Defibrillators, Implantable, Pacemaker, Artificial, Tomography, X-Ray Computed. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Despite technical advances, transvenous lead extraction (TLE) remains a challenging procedure. Cardiac computed tomography (CT) has emerged as a valuable tool for pre-procedural assessment, but its role in predicting outcomes in rotational mechanical TLE as a first-line strategy is not well defined. The aim was to determine whether pre-procedural CT can predict complications and procedural complexity in patients undergoing rotational mechanical TLE. Methods and results This retrospective study included 115 patients. All had pre-procedural contrast-enhanced CT with a dedicated lead extraction protocol. Two procedural outcomes were evaluated: (i) complicated procedure, defined as major complication, incomplete lead removal, or snare use, and (ii) complex procedure, defined as requiring either a snare or a tissue stabilization sheath. Logistic regression and receiver operating characteristic analyses were used to identify predictors. A total of 215 leads were extracted (mean dwelling time 95 ± 73 months). Complicated procedures occurred in 20.9% and were independently associated with longest fibrosis length on CT (odds ratio 1.1; P < 0.001); a fibrosis length of >40 mm predicted complicated procedures [area under the curve (AUC) 0.92; 95% confidence interval (CI) 0.88–0.97]. Complex procedures occurred in 37.4% and were associated with longest fibrosis length, lead calcification, dwelling time, and systolic heart failure. A fibrosis length of >30 mm predicted complex procedures (AUC 0.72; 95% CI 0.64–0.81).

Conclusion

Pre-procedural CT allows accurate identification of high-risk anatomical features, particularly fibrosis length and calcifications, which independently predict both complicated and complex rotational mechanical TLE. These findings support the integration of CT imaging into procedural planning and individualized risk stratification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Device RemovalDefibrillators, ImplantablePacemaker, ArtificialTomography, X-Ray ComputedPostoperative ComplicationsHumansMaleFemaleRetrospective StudiesAgedPredictive Value of TestsMiddle AgedRisk FactorsTreatment OutcomeAged, 80 and overROC CurveDevice Lead Extraction

Stichwörter der Autor:innen

ComplicationsComputed tomographyRisk stratificationRotational mechanical sheaths

Autor:innen und Institutionen

  • Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via N. Giustiniani 2, Padua 35121, Italy.
  • Cardiothoracic Surgery, Bristol Heart Institute, University of Bristol, Bristol, UK.
  • Radiology Unit, University of Padua-Azienda Ospedaliera, Padua, Italy.

ORCID-Profile: Federico Migliore, Raimondo Pittorru, Manuel De Lazzari, Giulia Winnicki, Marco Gemelli, Davide Margheri, Raffaella Motta, Valeria Pergola, Gino Gerosa, Domenico Corrado

Zitieren

APA

Migliore, F., Pittorru, R., Tarzia, V., Rosso, J., De Lazzari, M., Ziggiotto, A., Zancanaro, G., Winnicki, G., Gemelli, M., Micciolo, M., Guerrieri, A., Margheri, D., Motta, R., Pergola, V., Gerosa, G., & Corrado, D. (2025). Pre-procedural computed tomography predicts procedural complexity and complications in bidirectional rotational mechanical transvenous lead extraction. Europace, 27(12). https://doi.org/10.1093/europace/euaf308

Vancouver

Migliore F, Pittorru R, Tarzia V, Rosso J, De Lazzari M, Ziggiotto A, et al. Pre-procedural computed tomography predicts procedural complexity and complications in bidirectional rotational mechanical transvenous lead extraction. Europace. 2025;27(12). doi:10.1093/europace/euaf308

BibTeX
@article{Migliore2025,
  author = {Migliore, Federico and Pittorru, Raimondo and Tarzia, Vincenzo and Rosso, Jacopo and De Lazzari, Manuel and Ziggiotto, Andrea and Zancanaro, Gaia and Winnicki, Giulia and Gemelli, Marco and Micciolo, Matteo and Guerrieri, Antonio and Margheri, Davide and Motta, Raffaella and Pergola, Valeria and Gerosa, Gino and Corrado, Domenico},
  title = {Pre-procedural computed tomography predicts procedural complexity and complications in bidirectional rotational mechanical transvenous lead extraction},
  journal = {Europace},
  year = {2025},
  volume = {27},
  number = {12},
  doi = {10.1093/europace/euaf308}
}
Kostenlos starten →