Aveir retrievable, 38‐mm length, leadless pacemaker implantation in a 23‐kg pediatric patient with congenital heart disease
Pacing and Clinical Electrophysiology · 2024
DOI: 10.1111/pace.14934 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2024. Verfasst von Jacob Rodriguez und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, UC Davis Medical Center, Sacramento, USA. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Pacemaker, Artificial, Heart Defects, Congenital. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Complications are more prevalent in pediatric patients receiving pacemaker implants.
Methods
We performed a retrospective review of a retrievable, 38 mm leadless pacemaker implantation in a 23‐kg pediatric patient. Case/discussion An active 9‐year‐old, 23 kg male patient with tetralogy of Fallot with intermittent pacing need presented with a fractured lead and pacing need. He underwent implant of a retrievable leadless pacemaker (Abbott Aveir) via internal jugular vein access, without complication, and with echocardiographic guidance. His threshold was stable at 1.25 V @0.4 ms, with stable impedance and sensing at 5‐month follow‐up.
Conclusion
Aveir retrievable leadless pacemakers can be implanted safely in a child with tetralogy of Fallot, as small as 23 kilograms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, UC Davis Medical Center, Sacramento, USA.
- Santa Clara University, Santa Clara, USA.
Zitieren
APA
Rodriguez, J., & Cortez, D. (2024). Aveir retrievable, 38‐mm length, leadless pacemaker implantation in a 23‐kg pediatric patient with congenital heart disease. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14934
Vancouver
Rodriguez J, Cortez D. Aveir retrievable, 38‐mm length, leadless pacemaker implantation in a 23‐kg pediatric patient with congenital heart disease. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.14934
BibTeX
@article{Rodriguez2024,
author = {Rodriguez, Jacob and Cortez, Daniel},
title = {Aveir retrievable, 38‐mm length, leadless pacemaker implantation in a 23‐kg pediatric patient with congenital heart disease},
journal = {Pacing and Clinical Electrophysiology},
year = {2024},
doi = {10.1111/pace.14934}
}
EUVIMED