EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

3D ‐printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor

Yuxuan Zhang, Yi Guo, Zonghao Li, Bing Wang, Zhenfeng Li iD

Orthopaedic Surgery · 2024

DOI: 10.1111/os.14075 ↗

At a glance

Journal article in Orthopaedic Surgery, 2024. Written by Yuxuan Zhang and 4 co-authors. Institution: Department of Orthopedics, Qilu Hospital of Shandong University, Jinan, China. Major MEDLINE topics: Printing, Three-Dimensional, Bone Plates, Bone Screws, Femoral Neoplasms. Cited 2 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Natural Science Foundation of Shandong Province.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The accurate fenestration, screw implantation and assisting stabilizing‐plate placement in surgery of benign tumors in the proximal femur needs be defined easily. The aim of this study was to investigate the value of 3D printed multifunctional guides plate (3D‐MGP) based on computer aided design. Between January 2020 and June 2022, 17 patients (nine females and eight males) with benign proximal femoral tumor had lesion curettage and allograft combined with internal plate fixation using 3D‐MGP. In this study, the patients had CT scans and a technician reconstructed the 3D images of tumor and the femur, a doctor designed the location and margin of the fenestration and screws, and integrated different functions into MGP for benign proximal femoral lesions, which assisted in precise localization, fenestration and screw drilling. Musculoskeletal Tumor Society (MSTS) scoring was used to evaluate lower extremity function. Bone healing and the screws location was assessed with the radiographs. All patients underwent successful surgery with complete resection of the tumor and internal fixation with using the 3D‐MGP. The mean follow‐up was 16.4 months. The operative time was 126.47 ± 18.44 min, intraoperative bleeding was 198.23 ± 67.94 mL, intraoperative fluoroscopy was 6.47 ± 0.62, postoperative drainage was 223.82 ± 119.51 mL, and MSTS score was 27.29 ± 1.31 points. There were no unplanned fenestration and improper screw fixation. The 3D‐MGP enabled personalized and accurate location of tumor, fenestration, screw placement and assisted stabilizing‐plate placement for the treatment of benign tumor of the proximal femur. This technique has the potential to shorten operative times, decrease intraoperative bleeding, and reduce radiation exposure to patients.

Subjects

MeSH terms (MEDLINE)

Printing, Three-DimensionalBone PlatesBone ScrewsFemoral NeoplasmsHumansFemaleMaleAdultMiddle AgedYoung AdultComputer-Aided DesignAdolescent

Author keywords

3D‐printedFenestration guideMultifunctional guideProximal femurScrew drill guide

Authors and institutions

  • Department of Orthopedics, Qilu Hospital of Shandong University, Jinan, China.
  • Montefiore Medical Center, Albert Einstein School of Medicine, New York, New York, USA.
  • School of Mechanical Engineering, Shandong University, Jinan, China.

ORCID profiles: Zhenfeng Li

Funding

  • Natural Science Foundation of Shandong Province

Cite

APA

Zhang, Y., Guo, Y., Li, Z., Wang, B., & Li, Z. (2024). 3D ‐printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor. Orthopaedic Surgery. https://doi.org/10.1111/os.14075

Vancouver

Zhang Y, Guo Y, Li Z, Wang B, Li Z. 3D ‐printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor. Orthopaedic Surgery. 2024. doi:10.1111/os.14075

BibTeX
@article{Zhang2024,
  author = {Zhang, Yuxuan and Guo, Yi and Li, Zonghao and Wang, Bing and Li, Zhenfeng},
  title = {3D ‐printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor},
  journal = {Orthopaedic Surgery},
  year = {2024},
  doi = {10.1111/os.14075}
}
Start for free →