EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument

Emilia Gryska, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Per Fredrikson, Anders Björkman

Journal of Plastic Surgery and Hand Surgery · 15.05.2024 · 59 · 46-52

DOI: 10.2340/jphs.v59.39839 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic Surgery and Hand Surgery, online erschienen am 15.05.2024. Verfasst von Emilia Gryska und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Goth…. Hauptthemen laut MEDLINE: Bone Plates, Osteotomy, Radius Fractures, Fractures, Malunited. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63–74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesOsteotomyRadius FracturesFractures, MalunitedFracture Fixation, InternalHumansFemaleMiddle AgedAgedPrinting, Three-DimensionalSurgery, Computer-AssistedImaging, Three-DimensionalBone ScrewsTomography, X-Ray Computed

Autor:innen und Institutionen

  • Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. emilia.gryska@gu.se.
  • Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Medical Physics and Biomedic…
  • Sahlgrenska University Hospital, University of Gothenburg.

Zitieren

APA

Gryska, E., Libberecht, K., Stor Swinkels, C., Axelsson, P., Fredrikson, P., & Björkman, A. (2024). Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument. Journal of Plastic Surgery and Hand Surgery, 59, 46-52. https://doi.org/10.2340/jphs.v59.39839

Vancouver

Gryska E, Libberecht K, Stor Swinkels C, Axelsson P, Fredrikson P, Björkman A. Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument. Journal of Plastic Surgery and Hand Surgery. 2024;59:46-52. doi:10.2340/jphs.v59.39839

BibTeX
@article{Gryska2024,
  author = {Gryska, Emilia and Libberecht, Katleen and Stor Swinkels, Charlotte and Axelsson, Peter and Fredrikson, Per and Björkman, Anders},
  title = {Improving standard volar plate fixation in 3D-guided corrective osteotomy of the distal radius: evaluation of a shim instrument},
  journal = {Journal of Plastic Surgery and Hand Surgery},
  year = {2024},
  volume = {59},
  pages = {46--52},
  doi = {10.2340/jphs.v59.39839}
}
Kostenlos starten →