EUVIMEDDescubrir EUVIMED
Open access · CC BY-NC-ND 4.0

Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis

Xiaomeng Zhang, Yanhua Wang, Lijia Zhang, Kai Yu, Zhentao Ding, Yichong Zhang, Xiaofeng Chen, Chen Xiong iD, Yun Ji, Dianying Zhang iD, Xinlong Ma

Orthopaedic Surgery · 2023

DOI: 10.1111/os.13653 ↗

At a glance

Journal article in Orthopaedic Surgery, 2023. Written by Xiaomeng Zhang and 10 co-authors. Institution: Key Laboratory of Ministry of Education for Trauma Treatment and Nerve Regeneration, National Center for Trauma Medicine, Department of Orthopaedics …. Major MEDLINE topics: Arthroplasty, Replacement, Hip, Hip Prosthesis. Cited 6 times so far (Crossref); 32 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Innovative Research Team of Ministry of Education of China, College Construction Project of Peking University Health Science Center (2020)-National Trauma Medical Center, College Construction Project of Peking University Health Science Center (2020)-Key Laboratory of Trauma Treatment and Nerve Regeneration of Ministry of Educati….

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Objective

Compared with total hip replacement, conventional collum femoris preserving prosthesis has a better bone retention effect. However, damage to the trabecular bone of the proximal femur leads to inevitable abnormal stress distribution, which leads to increased risks of femoral neck bone absorption, periprosthetic fracture, prosthesis loosening, rotation, and sinking. Thus, we compare the biomechanical properties of collum femoris preserving (CFP) and bionic collum femoris preserving (BCFP) hip prostheses.

Methods

The Sawbone digital model (#3503, left, medium) was selected as the research object. We used the Mimics 21.0 software to reconstruct the digital model of the femur and the SolidWorks 2019 software to build and assemble the three‐dimensional models of CFP and BCFP prostheses. With the ANSYS Workbench 2021R1 software, the models were meshed and assigned values to simulate the load of a single foot under slow walking. We measured the mechanical distribution of the whole model and obtained the stress nephogram.

Results

For CFP prosthesis, the peak stresses of the medial interface of the stem neck, the lateral interface of the stem neck, and the end of the stem were 64.894, 32.199, and 8.578 MPa, respectively; the peak stresses of the medial surface of the femoral shaft, the lateral surface of femoral shaft, the medial femoral neck bone‐prosthesis interface (osteotomy interface), the lateral femoral neck bone‐prosthesis interface (basal area), the lateral femoral neck bone‐prosthesis interface (osteotomy interface), and the greater trochanter area were 28.093, 24.790, 14.388, 5.118, 4.179, and 8.245 MPa, respectively; the valley stress of the greater trochanter area was 1.134 MPa. For BCFP prosthesis, the peak stresses of the medial interface of the stem neck, the lateral interface of the stem neck, and the end of the stem were 47.015, 26.771, and 47.593 MPa, respectively; the peak stress of tension screw was 15.739 MPa; the peak stresses of the medial surface of the femoral shaft, the lateral surface of femoral shaft, the medial femoral neck bone‐prosthesis interface (osteotomy interface), the lateral femoral neck bone‐prosthesis interface (basal area), the lateral femoral neck bone‐prosthesis interface (osteotomy interface) and the greater trochanter area were 28.581, 25.364, 15.624, 6.434, 4.986, and 8.796 MPa, respectively; the valley stress of the greater trochanter area was 1.419 MPa; the peak stress of bone‐metal interface between the tension screw and the lateral surface of the femur was 5.858 MPa.

Conclusion

Compared with the CFP prosthesis, the design of the BCFP prosthesis is based on the lever balance theory. With the bionic reconstruction of tension trabeculae, BCFP prosthesis makes up for the defects of CFP prosthesis design, optimizes the stress distribution, and reduces the stress shelter effect of the proximal femur, which has better biomechanical properties.

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHumansFemur NeckBionicsFinite Element AnalysisFemurProsthesis DesignBiomechanical Phenomena

Author keywords

ArthroplastyBiomechanicsFemoral Neck FractureFinite Element AnalysisHipProsthetic FailureReplacement

Authors and institutions

  • Key Laboratory of Ministry of Education for Trauma Treatment and Nerve Regeneration, National Center for Trauma Medicine, Department of Orthopaedics and Traumatology, Peking University People's Hospital, Beijing, China.
  • Department of Orthopaedics, Peking Union Medical College Hospital, Beijing, China.
  • Department of Orthopaedics, Tianjin Fifth Central Hospital, Tianjin, China.
  • Department of Orthopaedics, Tianjin Hospital, Tianjin, China.

ORCID profiles: Chen Xiong, Dianying Zhang

Funding

  • Innovative Research Team of Ministry of Education of China
  • College Construction Project of Peking University Health Science Center (2020)-National Trauma Medical Center
  • College Construction Project of Peking University Health Science Center (2020)-Key Laboratory of Trauma Treatment and Nerve Regeneration of Ministry of Educati…
  • Construction Project of Peking University People's Hospital (2021)-National Trauma Medical Center
  • Construction project of Peking University People's Hospital-Key Laboratory of Trauma Treatment and Nerve Regeneration of Ministry of Education
  • National Key Research and Development Program
  • Tianjin Municipal Health Commission Scientific Research Project
  • National Key Research and Development Program of China

Cite

APA

Zhang, X., Wang, Y., Zhang, L., Yu, K., Ding, Z., Zhang, Y., Chen, X., Xiong, C., Ji, Y., Zhang, D., & Ma, X. (2023). Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis. Orthopaedic Surgery. https://doi.org/10.1111/os.13653

Vancouver

Zhang X, Wang Y, Zhang L, Yu K, Ding Z, Zhang Y, et al. Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis. Orthopaedic Surgery. 2023. doi:10.1111/os.13653

BibTeX
@article{Zhang2023,
  author = {Zhang, Xiaomeng and Wang, Yanhua and Zhang, Lijia and Yu, Kai and Ding, Zhentao and Zhang, Yichong and Chen, Xiaofeng and Xiong, Chen and Ji, Yun and Zhang, Dianying and Ma, Xinlong},
  title = {Biomechanical Properties of Bionic Collum Femoris Preserving Hip Prosthesis: A Finite Element Analysis},
  journal = {Orthopaedic Surgery},
  year = {2023},
  doi = {10.1111/os.13653}
}
Start for free →