EUVIMEDΑνακαλύψτε το EUVIMED
Crossref

Effect of Immediate Loading on the Stability of Orthodontic Mini‐Implant—An Ex Vivo Study

Tehchai Richard Chang iD, K Pradeep iD, C V Padma Priya iD, Manda Anoosha iD, N Hari Babu iD, Avichal Singh Sodhi iD

Orthodontics & Craniofacial Research · 2026-12 · 29 (6) · 1094-1099

DOI: 10.1111/ocr.70155 ↗

At a glance

Journal article in Orthodontics & Craniofacial Research, published online on 2026-07-14. Written by Tehchai Richard Chang and 5 co-authors. Institution: Department of Orthodontics, Vishnu Dental College, Bhimavaram, India. Major MEDLINE topics: Orthodontic Anchorage Procedures, Dental Implants, Immediate Dental Implant Loading. 12 references.

ΠερίληψηSubjectsΒιβλιογραφικά στοιχείαCiteRelated studies

Abstract (original language)

Introduction

Mini‐implant placement has become a routine method for providing anchorage in orthodontic treatment. The stability of these implants is influenced by several factors, including implant design, bone quality, site preparation, insertion angle, and loading protocol. Among these, implant and bone quality are largely unmodifiable. Resonance Frequency Analysis (RFA) is widely used to assess implant stability. This ex vivo study aimed to evaluate the impact of immediate loading on the stability of orthodontic mini‐implants using RFA. Materials and Methods This prospective animal study assessed the primary stability of 72 self‐drilling stainless steel mini‐implants of three lengths (1.3 mm × 6 mm, 1.3 mm × 8 mm, and 1.3 mm × 10 mm). A 2 N load was applied using nickel–titanium coil springs. Stability was measured by RFA immediately after force application (T0) and after 5 weeks (T1).

Results

Initial stability was comparable across all implant lengths. After 5 weeks of loading, all groups demonstrated a reduction in stability. The 6 mm implants showed a significantly greater loss of stability (5.31 ± 4.89) compared to the 8 mm (2.36 ± 4.08) and 10 mm (2.39 ± 1.64) implants. All lengths exhibited statistically significant stability loss post‐loading (6 mm, p = 0.001; 8 mm, p = 0.009; 10 mm, p = 0.001).

Conclusion

Variations in implant length did not significantly affect immediate stability following loading. However, over time, 6 mm implants experienced greater stability loss compared to 8 mm and 10 mm implants. Despite this, shorter implants exhibited slightly higher initial stability under load.

Subjects

MeSH terms (MEDLINE)

Orthodontic Anchorage ProceduresDental ImplantsImmediate Dental Implant LoadingAnimalsResonance Frequency AnalysisProspective StudiesDental Stress AnalysisOrthodontic Appliance DesignTitaniumStainless Steel

Author keywords

immediate loadingmini‐implantsprimary stabilityresonance frequency analysis

Substances

Dental ImplantsTitaniumStainless Steel

Authors and institutions

  • Department of Orthodontics, Vishnu Dental College, Bhimavaram, India.

ORCID profiles: Tehchai Richard Chang, K Pradeep, C V Padma Priya, Manda Anoosha, N Hari Babu, Avichal Singh Sodhi

Cite

APA

Chang, T. R., Pradeep, K., Padma Priya, C. V., Anoosha, M., Hari Babu, N., & Sodhi, A. S. (2026). Effect of Immediate Loading on the Stability of Orthodontic Mini‐Implant—An Ex Vivo Study. Orthodontics & Craniofacial Research, 29(6), 1094-1099. https://doi.org/10.1111/ocr.70155

Vancouver

Chang TR, Pradeep K, Padma Priya CV, Anoosha M, Hari Babu N, Sodhi AS. Effect of Immediate Loading on the Stability of Orthodontic Mini‐Implant—An Ex Vivo Study. Orthodontics & Craniofacial Research. 2026;29(6):1094-1099. doi:10.1111/ocr.70155

BibTeX
@article{Chang2026,
  author = {Chang, Tehchai Richard and Pradeep, K and Padma Priya, C V and Anoosha, Manda and Hari Babu, N and Sodhi, Avichal Singh},
  title = {Effect of Immediate Loading on the Stability of Orthodontic Mini‐Implant—An Ex Vivo Study},
  journal = {Orthodontics & Craniofacial Research},
  year = {2026},
  volume = {29},
  number = {6},
  pages = {1094--1099},
  doi = {10.1111/ocr.70155}
}
Start for free →