Comparison Between Stainless Steel and Polyetheretherketone (PEEK) Temporary Anchorage Devices in Orthodontics - A Comparative Study
Indian Journal of Dental Research · 2025
DOI: 10.4103/ijdr.ijdr_153_25 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Indian Journal of Dental Research, 2025. Verfasst von Eduardo Pérez Maldonado Barragán und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Universidad Europea de Madrid, Madrid, Spain. Hauptthemen laut MEDLINE: Stainless Steel, Polyethylene Glycols, Ketones, Orthodontic Anchorage Procedures. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Mini-implants are crucial in orthodontics for absolute anchorage, allowing precise dental movements without affecting adjacent structures. Exploring alternative materials with proven biocompatibility and potential for improved clinical performance is essential. This study compares the mechanical resistance of polyetheretherketone (PEEK) and stainless steel mini-implants to evaluate PEEK’s feasibility as an alternative.
Objectives
To compare PEEK and stainless steel for orthodontic mini-implants, focusing on maximum load resistance and suitability for temporary anchorage. Materials and Methods: Two groups of 12 mini-implants (2 mm × 8 mm) were tested: milled PEEK and stainless steel (TD Orthodontics©, Nuevo León, Mexico). Both mini-implants were inserted into porcine mandibles, sectioned placed in acrylic bases and subjected to maximum load tests using a universal testing machine. Data normality was assessed with the Shapiro–Wilk test and variances with Levene’s test. Comparisons were performed using Welch’s t -test (α = 0.05), with effect sizes (Hedges’ g) and 95% confidence intervals reported.
Results
Stainless steel mini-implants showed a mean maximum load of 255.77 N whereas PEEK averaged 57.14 N after outlier adjustment. Welch’s t -test confirmed a significant difference between groups ( P < 0.001) with a large effect size (Hedges’ g = 2.31). Statistically significant differences were observed between groups, with a mean difference of 198.6 N (95% CI 126.3–271.0).
Conclusion
Although stainless steel exhibited greater load resistance, PEEK mini-implants exceeded clinically relevant orthodontic forces (50–400 g), supporting their potential as temporary anchorage devices. Further in vivo and clinical studies are needed to confirm long-term performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Dentistry, Universidad Europea de Madrid, Madrid, Spain.
- Master's Program in Dental Sciences, Faculty of Odontology, Laguna Unit, Autonomous University of Coahuila, Torreón, Coahuila, Mexico.
- Department of Basic Sciences and Engineering, Universidad Autónoma del Estado de Hidalgo, Pachuca, Hidalgo, Mexico.
- Department of Orthodontics, Universidad AME, Nuevo León, Mexico.
Zitieren
APA
Pérez Maldonado Barragán, E., Navarro Villalobos, M., García Rosas, S. J., Ojeda Misses, M. A., & Gómez Obregón, E. (2025). Comparison Between Stainless Steel and Polyetheretherketone (PEEK) Temporary Anchorage Devices in Orthodontics - A Comparative Study. Indian Journal of Dental Research. https://doi.org/10.4103/ijdr.ijdr_153_25
Vancouver
Pérez Maldonado Barragán E, Navarro Villalobos M, García Rosas SJ, Ojeda Misses MA, Gómez Obregón E. Comparison Between Stainless Steel and Polyetheretherketone (PEEK) Temporary Anchorage Devices in Orthodontics - A Comparative Study. Indian Journal of Dental Research. 2025. doi:10.4103/ijdr.ijdr_153_25
BibTeX
@article{PrezMaldonadoBarragn2025,
author = {Pérez Maldonado Barragán, Eduardo and Navarro Villalobos, Mauricio and García Rosas, Santiago J and Ojeda Misses, Manuel A and Gómez Obregón, Edgar},
title = {Comparison Between Stainless Steel and Polyetheretherketone (PEEK) Temporary Anchorage Devices in Orthodontics - A Comparative Study},
journal = {Indian Journal of Dental Research},
year = {2025},
doi = {10.4103/ijdr.ijdr_153_25}
}
EUVIMED