Randomisierte kontrollierte Studie in der Zeitschrift Clinical and Experimental Dental Research, online erschienen am 25.10.2026. Verfasst von Paolo Carosi und 5 weiteren Autor:innen. Beteiligte Einrichtung: CL Dentistry, Segni, Italy. Hauptthemen laut MEDLINE: Dental Implants, Immediate Dental Implant Loading, Dental Prosthesis Design. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institut Straumann.
Abstract (Originalsprache)
Objectives
To compare the early stability trajectories of two tissue‐level implant macro‐designs after immediate placement, using monthly resonance frequency analysis (ISQ) over 6 months. Materials and Methods Single‐center randomized clinical trial in adults requiring immediate implant placement in posterior sites. ISQ was recorded at implant placement and monthly for 6 months. A linear mixed‐effects model (subject‐level random intercept; fixed effects for group, visit, their interaction, and baseline ISQ) was fitted, with the group × visit interaction as the primary inferential term. The 6‐month endpoint was assessed by baseline‐adjusted ANCOVA, with equivalence tested against a ±3 ISQ margin (2 one‐sided tests).
Results
Thirty implants were placed in 30 patients (aggressive self‐tapping, n = 15; conservative uniform‐thread, n = 15). ISQ increased significantly over time in both groups ( p < 0.001). The group × visit interaction was significant (χ 2 = 43.25, df = 5, p < 0.001); baseline‐adjusted differences favored the aggressive design at t1 (+3.84 ISQ, 95% CI 1.64 to 6.03; p = 0.004) and t2 (+3.70, 95% CI 1.51 to 5.90; p = 0.005), and were no longer detectable from t3. At 6 months, the baseline‐adjusted difference was −0.73 ISQ (95% CI −2.91 to 1.46; p = 0.500), and equivalence within ±3 ISQ was supported (TOST p = 0.021). All aggressive‐design implants reached ISQ ≥ 70 by 3 months versus 33% in the conservative group ( p = 0.001).
Conclusions
Within the limitations of this trial, the more aggressive macro‐design showed significantly higher stability during the first 2 months of healing, with significantly different trajectories over time, whereas at 6 months, no between‐group difference was demonstrated and equivalence within the pre‐specified ±3 ISQ margin was supported. Macro‐design therefore influenced the timing of stability acquisition rather than stability at 6 months, supporting its relevance for early loading protocols.
Trial registration
ClinicalTrials.gov identifier: NCT06711744; Date of registration: 21 November 2024; EC Protocol ID: 6271 (Ethics Committee Lazio 3).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CL Dentistry, Segni, Italy.
- Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
- Department of Oral Pathology, Oral Medicine, and Oral & Maxillofacial Surgery, University of Tripoli School of Dentistry, Tripoli, Libya.
- Private practice, Salerno, Italy.
ORCID-Profile: Paolo Carosi, Andrea Laureti, Abdusalam Alrmali, Alessandro Pinto, Hom-Lay Wang
Förderung
- Institut Straumann
Zitieren
APA
Carosi, P., Laureti, A., Alrmali, A., Pinto, A., Wang, H. L., & Lorenzi, C. (2026). Design Matters? Evaluating Implant Macro‐Geometry in Immediate Implants: A Randomized Clinical Trial With Six‐Month Interim Analysis. Clinical and Experimental Dental Research, 12(5). https://doi.org/10.1002/cre2.70490
Vancouver
Carosi P, Laureti A, Alrmali A, Pinto A, Wang HL, Lorenzi C. Design Matters? Evaluating Implant Macro‐Geometry in Immediate Implants: A Randomized Clinical Trial With Six‐Month Interim Analysis. Clinical and Experimental Dental Research. 2026;12(5). doi:10.1002/cre2.70490
BibTeX
@article{Carosi2026,
author = {Carosi, Paolo and Laureti, Andrea and Alrmali, Abdusalam and Pinto, Alessandro and Wang, Hom-Lay and Lorenzi, Claudia},
title = {Design Matters? Evaluating Implant Macro‐Geometry in Immediate Implants: A Randomized Clinical Trial With Six‐Month Interim Analysis},
journal = {Clinical and Experimental Dental Research},
year = {2026},
volume = {12},
number = {5},
doi = {10.1002/cre2.70490}
}
EUVIMED