Fachartikel in der Zeitschrift Microcirculation, online erschienen am 29.12.2022. Verfasst von Goksel Guven und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intensive Care, Erasmus MC, Rotterdam, The Netherlands. Hauptthemen laut MEDLINE: Laser Speckle Contrast Imaging, Perfusion Imaging. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Health~Holland, PPP Allowance, Dutch Burns Foundation.
Abstract (Originalsprache)
Objective
Laser‐based tissue perfusion monitoring techniques have been increasingly used in animal and human research to assess blood flow. However, these techniques use arbitrary units, and knowledge about their comparability is scarce. This study aimed to model the relationship between laser speckle contrast imaging (LSCI) and laser Doppler perfusion imaging (LDPI), for measuring tissue perfusion over a wide range of blood flux values.
Methods
Fifteen healthy volunteers (53% female, median age 29 [IQR 22–40] years) were enrolled in this study. We performed iontophoresis with sodium nitroprusside on the forearm to induce regional vasodilation to increase skin blood flux. Besides, a stepwise vascular occlusion was applied on the contralateral upper arm to reduce blood flux. Both techniques were compared using a linear mixed model analysis.
Results
Baseline blood flux values measured by LSCI were 33 ± 6.5 arbitrary unit (AU) (Coefficient of variation [CV] = 20%) and by LDPI 60 ± 11.5 AU (CV = 19%). At the end of the iontophoresis protocol, the regional blood flux increased to 724 ± 412% and 259 ± 87% of baseline measured by LDPI and LSCI, respectively. On the other hand, during the stepwise vascular occlusion test, the blood flux reduced to 212 ± 40% and 412 ± 177% of its baseline at LDPI and LSCI, respectively. A strong correlation was found between the LSCI and LDPI instruments at increased blood flux with respect to baseline skin blood flux; however, the correlation was weak at reduced blood flux with respect to baseline.
Discussion
LSCI and LDPI instruments are highly linear for blood flux higher than baseline skin blood flux; however, the correlation decreased for blood flux lower than baseline. This study's findings could be a basis for using LSCI in specific patient populations, such as burn care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Intensive Care, Erasmus MC, Rotterdam, The Netherlands.
- Departments of Trauma and Burn Surgery, Maasstad Ziekenhuis, Rotterdam, The Netherlands.
- Department of Internal Medicine, Division of Intensive Care, Hacettepe University Faculty of Medicine, Ankara, Turkey.
- Association of Dutch Burn Centers, Burn Center, Maasstad Ziekenhuis, Rotterdam, The Netherlands.
- Trauma Research Unit Department of Surgery, Erasmus MC, Rotterdam, The Netherlands.
ORCID-Profile: Goksel Guven
Förderung
- Health~Holland
- PPP Allowance
- Dutch Burns Foundation
- Nederlandse Brandwonden Stichting
Zitieren
APA
Guven, G., Dijkstra, A., Kuijper, T. M., Trommel, N., van Baar, M. E., Topeli, A., Ince, C., & van der Vlies, C. H. (2023). Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement. Microcirculation, 30(1). https://doi.org/10.1111/micc.12795
Vancouver
Guven G, Dijkstra A, Kuijper TM, Trommel N, van Baar ME, Topeli A, et al. Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement. Microcirculation. 2023;30(1). doi:10.1111/micc.12795
BibTeX
@article{Guven2023,
author = {Guven, Goksel and Dijkstra, Annemieke and Kuijper, Tjallingius Martijn and Trommel, Nicole and van Baar, Margriet Elisabeth and Topeli, Arzu and Ince, Can and van der Vlies, Cornelis Hendrik},
title = {Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement},
journal = {Microcirculation},
year = {2023},
volume = {30},
number = {1},
doi = {10.1111/micc.12795}
}
EUVIMED