EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Microvascular effects of a mixed meal tolerance test: a model validation study

Sebastiaan J W van Kraaij, Boukje Charlotte Eveleens Maarse, Femke P M Hoevenaars, Ines Warnke, Marieke L de Kam, Matthijs Moerland, Pim Gal

Clinical Physiology and Functional Imaging · 2025

DOI: 10.1111/cpf.12904 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, 2025. Verfasst von Sebastiaan J W van Kraaij und 6 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Human Drug Research, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Microcirculation, Hyperemia, Predictive Value of Tests, Regional Blood Flow. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DSM, Centre for Human Drug Research, Nederlandse Organisatie voor Toegepast Natuurwetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Endothelial dysfunction is a pathophysiological change preceding many cardiovascular events. Measuring improvements of endothelial function is challenging when function is already optimal, which may be remediated using a physiological challenge. This study aimed to determine whether imaging assessments can detect microvascular effects of a mixed meal tolerance test (MMTT).

Methods

Twenty healthy volunteers (age ≥45 and ≤70 years) underwent two MMTTs at the beginning (Day 1) and end (Day 84) of a twelve‐week period. Imaging methods included laser speckle contrast imaging (LSCI) combined with post‐occlusive reactive hyperaemia (PORH) and local thermal hyperaemia (LTH) challenges, passive leg movement ultrasonography (PLM), and sidestream dark field microscopy (SDFM). Measurements were conducted pre‐MMTT and at 5 timepoints post‐MMTT for PLM and SDFM and 3 timepoints post‐MMTT for PORH and LTH.

Results

No consistent effects of the MMTT were detected on LSCI LTH, PLM and SDFM endpoints. LSCI PORH maximum perfusion was significantly suppressed 46, 136, and 300 min post‐MMTT administration on Day 1, while residual perfusion decreased significantly 46 and 136 min post‐MMTT on Day 1. However, when repeated on Day 84, PORH endpoints were not significantly affected by the MMTT.

Conclusion

SDFM, PLM and LSCI LTH endpoints displayed high intra‐subject variability and did not detect consistent effects of MMTT. LSCI PORH endpoints displayed the lowest intra‐subject variability of all assessed endpoints and were affected by the MMTT on Day 1, but not on Day 84. Further standardization of methods or more robust challenges to affect vascular endpoints may be needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrocirculationHyperemiaPredictive Value of TestsRegional Blood FlowLaser Speckle Contrast ImagingHumansMaleFemaleMiddle AgedReproducibility of ResultsTime FactorsAgedHealthy VolunteersMicrovesselsBlood Flow VelocityMealsUltrasonography

Stichwörter der Autor:innen

endothelial functionlaser speckle contrast imagingpassive leg movementsidestream dark field microscopy

Autor:innen und Institutionen

  • Centre for Human Drug Research, Leiden, The Netherlands.
  • Leiden University Medical Centre, Leiden, The Netherlands.
  • TNO, Netherlands Organisation for Applied Scientific Research, Leiden, The Netherlands.
  • dsm-firmenich, CH-4303, Kaiseraugst, Switzerland.

Förderung

  • DSM
  • Centre for Human Drug Research
  • Nederlandse Organisatie voor Toegepast Natuurwetenschappelijk Onderzoek

Zitieren

APA

van Kraaij, S. J. W., Eveleens Maarse, B. C., Hoevenaars, F. P. M., Warnke, I., de Kam, M. L., Moerland, M., & Gal, P. (2025). Microvascular effects of a mixed meal tolerance test: a model validation study. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12904

Vancouver

van Kraaij SJW, Eveleens Maarse BC, Hoevenaars FPM, Warnke I, de Kam ML, Moerland M, et al. Microvascular effects of a mixed meal tolerance test: a model validation study. Clinical Physiology and Functional Imaging. 2025. doi:10.1111/cpf.12904

BibTeX
@article{vanKraaij2025,
  author = {van Kraaij, Sebastiaan J W and Eveleens Maarse, Boukje Charlotte and Hoevenaars, Femke P M and Warnke, Ines and de Kam, Marieke L and Moerland, Matthijs and Gal, Pim},
  title = {Microvascular effects of a mixed meal tolerance test: a model validation study},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2025},
  doi = {10.1111/cpf.12904}
}
Kostenlos starten →