EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Cutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli

Tomas Strömberg, Nina Berggren, Marcus Larsson, Ingemar Fredriksson, Martin Hultman

Microvascular Research · 2026

DOI: 10.1016/j.mvr.2026.104987 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Microvascular Research, 2026. Verfasst von Tomas Strömberg und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Linköping University, Linköping, Sweden. Electronic address: tomas.stromberg@liu.se. Hauptthemen laut MEDLINE: Microcirculation, Skin, Foot, Perfusion Imaging. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sweden's Innovation Agency, Swedish Foundation for Strategic Research, Linköping University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Skin microvascular reactivity tests for the lower extremity apply stimuli such as ankle occlusion (post-occlusive reactive hyperemia, PORH), local heating (LH), or the vasoactive drug methyl nicotinate (MN). AIM: Evaluate microvascular reactivity in dorsal foot skin comparing PORH, LH and MN stimuli. METHOD: Thirty healthy participants 20-65 years of age were enrolled in a protocol using pointwise and imaging optical techniques for perfusion and oxygen saturation. Mean values and between-subjects coefficient of variation (CV) for perfusion and oxygen saturation were compared. RESULTS: The PORH, LH and MN stimuli caused significant increases in oxygen saturation and perfusion from baseline values (p 30%. CONCLUSION: The responses in oxygen saturation and perfusion were higher during MN and LH stimuli than for PORH. A few outliers were observed after MN with a slower and lower response. Microcirculatory oxygen saturation has a lower between-subjects variation than perfusion (CV 3-7% vs >30%) during PORH, LH and MN stimuli.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrocirculationSkinFootPerfusion ImagingLaser-Doppler FlowmetryMicrovesselsLaser Speckle Contrast ImagingMultimodal ImagingHumansAdultMiddle AgedFemaleMaleRegional Blood FlowPredictive Value of TestsAgedBlood Flow VelocityOxygen SaturationYoung AdultHyperemiaVasodilator AgentsNicotinic AcidsHot TemperatureTime Factors

Stichwörter der Autor:innen

Diffuse reflectance spectroscopyLaser Doppler flowmetryMethyl nicotinateMicrocirculationMulti-exposure laser speckle contrast imagingMultispectral imagingSkin

Substanzen

methyl nicotinateVasodilator AgentsNicotinic Acids

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Linköping University, Linköping, Sweden. Electronic address: tomas.stromberg@liu.se.
  • Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
  • Department of Biomedical Engineering, Linköping University, Linköping, Sweden; Perimed AB, Datavägen 9A, Järfälla, Stockholm, Sweden.

Förderung

  • Sweden's Innovation Agency
  • Swedish Foundation for Strategic Research
  • Linköping University

Zitieren

APA

Strömberg, T., Berggren, N., Larsson, M., Fredriksson, I., & Hultman, M. (2026). Cutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli. Microvascular Research. https://doi.org/10.1016/j.mvr.2026.104987

Vancouver

Strömberg T, Berggren N, Larsson M, Fredriksson I, Hultman M. Cutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli. Microvascular Research. 2026. doi:10.1016/j.mvr.2026.104987

BibTeX
@article{Strmberg2026,
  author = {Strömberg, Tomas and Berggren, Nina and Larsson, Marcus and Fredriksson, Ingemar and Hultman, Martin},
  title = {Cutaneous microvascular reactivity in the foot evaluated by optical multimodal pointwise and imaging techniques and different stimuli},
  journal = {Microvascular Research},
  year = {2026},
  doi = {10.1016/j.mvr.2026.104987}
}
Kostenlos starten →