Printed versus heat‐polymerized resin for occlusal devices: Evaluation of physical and mechanical properties after brushing and microbial adhesion
Journal of Prosthodontics · 06.01.2025
DOI: 10.1111/jopr.14012 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 06.01.2025. Verfasst von João Marcos Carvalho-Silva und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Materials and Prosthesis, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: São Paulo Research Foundation (FAPESP), Unified Scholarship Program.
Abstract (Originalsprache)
Purpose
To evaluate the physical and mechanical properties after brushing and microbial adhesion of printed resins (PRs) and heat‐polymerized resins (HRs) for occlusal devices (ODs). Materials and Methods Knoop microhardness and roughness were evaluated in three measurements before and after brushing with detergent or dentifrice. Flexural strength and modulus of elasticity were assessed by 3‐point bending, and the adhesion of Candida albicans and Streptococcus mutans was evaluated by colony‐forming units per milliliter (CFU/mL) and metabolic activity using the XTT assay only without brushing. Flexural strength, modulus of elasticity, and microbial adhesion were analyzed using Student's t ‐test, while three‐way repeated‐measures ANOVA with post hoc Bonferroni was applied to evaluate microhardness and roughness ( p < 0.05).
Results
PR showed higher microhardness, lower microbial adhesion, and metabolic activity of C. albicans than HR ( p < 0.05), which in turn showed higher flexural strength and modulus of elasticity ( p < 0.05). There was no difference in the adhesion and metabolic activity of S. mutans or the roughness between the resins ( p > 0.05). Brushing with detergent and dentifrice reduced HR and PR microhardness ( p < 0.05); the use of detergent did not change HR and PR roughness ( p = 1.00), and the use of dentifrice increased HR roughness ( p < 0.001).
Conclusion
It was concluded that PR showed lower roughness and higher microhardness and lower microbial adhesion after brushing with dentifrice compared to HR. However, HR had higher flexural strength and modulus of elasticity than PR. The use of detergent did not promote surface changes for PR and HR after brushing.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dental Materials and Prosthesis, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil.
ORCID-Profile: Andréa Cândido Dos Reis
Förderung
- São Paulo Research Foundation (FAPESP)
- Unified Scholarship Program
Zitieren
APA
Carvalho-Silva, J. M., Marinho, V. T., Lopez, V. P., Teixeira, A. B. V., Ferreira, I., de Campos, M. R., & Dos Reis, A. C. (2025). Printed versus heat‐polymerized resin for occlusal devices: Evaluation of physical and mechanical properties after brushing and microbial adhesion. Journal of Prosthodontics. https://doi.org/10.1111/jopr.14012
Vancouver
Carvalho-Silva JM, Marinho VT, Lopez VP, Teixeira ABV, Ferreira I, de Campos MR, et al. Printed versus heat‐polymerized resin for occlusal devices: Evaluation of physical and mechanical properties after brushing and microbial adhesion. Journal of Prosthodontics. 2025. doi:10.1111/jopr.14012
BibTeX
@article{CarvalhoSilva2025,
author = {Carvalho-Silva, João Marcos and Marinho, Vanessa Teixeira and Lopez, Vitor de Paula and Teixeira, Ana Beatriz Vilela and Ferreira, Izabela and de Campos, Murilo Rodrigues and Dos Reis, Andréa Cândido},
title = {Printed versus heat‐polymerized resin for occlusal devices: Evaluation of physical and mechanical properties after brushing and microbial adhesion},
journal = {Journal of Prosthodontics},
year = {2025},
doi = {10.1111/jopr.14012}
}
EUVIMED