Übersichtsarbeit in der Zeitschrift Journal of Prosthodontics, online erschienen am 08.09.2023. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit wurde bisher 131-mal zitiert (Crossref) und nennt 88 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To report the means to maximize the predictability and accuracy of intraoral digital implant scans through the evaluation of operator and patient‐related factors. Materials and Methods A search of published articles related to factors that can decrease the scanning accuracy of intraoral digital implant scans was completed in four data sources:MEDLINE, EMBASE, EBSCO, and Web of Science. All studies related to variables that can influence the accuracy of intraoral digital implant scans obtained by using intraoral scanners (IOSs) were considered. These variables included ambient lighting, scanning pattern, implant scan body (ISB) design, techniques for splinting ISBs, arch location, implant position, and inter‐implant distance.

Results

Among operator‐related factors, ambient lighting conditions, scanning pattern, and ISB design (material, geometry, and retention design) can impact the accuracy of intraoral digital implant scans. The optimal ISB for maximizing IOS accuracy is unclear; however, polymer ISB can wear with multiple reuse and sterilization methods. Among patient‐related factors, additional variables should be considered, namely arch (maxillary vs. mandibular arch), implant position in the arch, inter‐implant distance, implant depth, and angulation.

Conclusions

Ambient lighting conditions should be established based on the IOS selected to optimize the accuracy of intraoral digital implant scans. The optimal scanning pattern may vary based on the IOS, clinical situation, and the number of implants. The optimal ISB design may vary depending on the IOS used. Metallic implant scan bodies are preferred over polymer ISB designs to minimize wear due to multiple use and sterilization distortion. Among patient‐related factors, additional variables should be considered namely the arch scanned, implant position in the arch, inter‐implant distance, implant depth, and angulation. The impact of these factors may vary depending on the IOS selected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsHumansImaging, Three-DimensionalDental Impression TechniqueComputer-Aided DesignModels, DentalPolymers

Stichwörter der Autor:innen

accuracydigital impressionsdigital scansimplant scansinfluencing factorsintraoral conditionsintraoral scannersoperator factorspatient factors

Substanzen

Dental ImplantsPolymers

Autor:innen und Institutionen

  • Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.
  • Kois Center, Seattle, Washington, USA.
  • Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.
  • Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.

ORCID-Profile: Marta Revilla-León, John C Kois

Zitieren

APA

Revilla-León, M., Lanis, A., Yilmaz, B., Kois, J. C., & Gallucci, G. O. (2023). Intraoral digital implant scans: Parameters to improve accuracy. Journal of Prosthodontics, 32(S2), 150-164. https://doi.org/10.1111/jopr.13749

Vancouver

Revilla-León M, Lanis A, Yilmaz B, Kois JC, Gallucci GO. Intraoral digital implant scans: Parameters to improve accuracy. Journal of Prosthodontics. 2023;32(S2):150-164. doi:10.1111/jopr.13749

BibTeX
@article{RevillaLen2023,
  author = {Revilla-León, Marta and Lanis, Alejandro and Yilmaz, Burak and Kois, John C and Gallucci, German O},
  title = {Intraoral digital implant scans: Parameters to improve accuracy},
  journal = {Journal of Prosthodontics},
  year = {2023},
  volume = {32},
  number = {S2},
  pages = {150--164},
  doi = {10.1111/jopr.13749}
}
Kostenlos starten →