EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative accuracy of digital impressions using universal dual‐purpose scan jigs for maxillary implant full arch impressions: An in vitro study

Abdulrahman Almalki iD, Mohammed A Akl iD, Ali Robaian, Ramzi Althubaitiy, Abdullah Alnasser, Evanthia Anadioti

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.14029 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Abdulrahman Almalki und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Prosthetic Dental Sciences Department, Prince Sattam bin Abdulaziz University, Alkharj, Saudi Arabia. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Implants. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the accuracy of intraoral scanners (IOSs) for final impressions using dual‐purpose scan jigs (DPSJs) and standard scan bodies (SBs). Materials and Methods An edentulous typodont model with multiunit abutment analogs in the lateral incisor (L), premolar (P), and molar (M) regions was used for intraoral scanning following the manufacturer's recommended protocol. This process involved digitally scanning standard SBs and DPSJs, with the obtained data superimposed and compared against the reference model. Three‐dimensional (3D) evaluation software (Geomagic Control X) was then employed to identify any deviations in the data, followed by statistical analysis using ANOVA one‐way tests and Bonferroni post hoc tests to determine differences at each location.

Results

The overall accuracy ranged from 21.8 to 16.8 µm for DPSJs and from 25.3 to 16.1 µm for SBs. Statistical analysis showed no significant differences between DPSJs and SBs across lateral incisor (L), premolar (P), and molar (M) locations. Specifically, SBs exhibited higher accuracy in lateral incisors (16.8 µm) compared to DPSJs (21.8 µm), but this difference lacked statistical significance. Similarly, in premolar locations, SBs were slightly more accurate (16.1 µm) than DPSJs (17.3 µm), with no statistical significance. Conversely, DPSJs showed slightly better accuracy in molar locations (17.3 µm) than SBs (19.1 µm), which was not statistically significant.

Conclusion

The in vitro study concluded that intraoral digital scanning with DPSJs showed comparable accuracy to standard scan bodies for fully edentulous arches. Furthermore, the 3D deviation of implant positions using both DPSJs and SBs fell within clinically acceptable ranges.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Impression TechniqueDental ImplantsHumansMaxillaIn Vitro TechniquesModels, DentalComputer-Aided DesignImaging, Three-DimensionalDental Arch

Stichwörter der Autor:innen

dental implantsdental prosthesesdigital dentistryfixed prosthodonticsintraoral scanning

Substanzen

Dental Implants

Autor:innen und Institutionen

  • The Prosthetic Dental Sciences Department, Prince Sattam bin Abdulaziz University, Alkharj, Saudi Arabia.
  • Division of Prosthodontics, Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota, USA.
  • Department of Coservative and Dental Sciences, College of Dentistry, Prince Sattam bin Abdulaziz Universiy, Al-Kharj, Saudi Arabia.
  • The Restorative Department, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

ORCID-Profile: Abdulrahman Almalki, Mohammed A Akl

Zitieren

APA

Almalki, A., Akl, M. A., Robaian, A., Althubaitiy, R., Alnasser, A., & Anadioti, E. (2025). Comparative accuracy of digital impressions using universal dual‐purpose scan jigs for maxillary implant full arch impressions: An in vitro study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.14029

Vancouver

Almalki A, Akl MA, Robaian A, Althubaitiy R, Alnasser A, Anadioti E. Comparative accuracy of digital impressions using universal dual‐purpose scan jigs for maxillary implant full arch impressions: An in vitro study. Journal of Prosthodontics. 2025. doi:10.1111/jopr.14029

BibTeX
@article{Almalki2025,
  author = {Almalki, Abdulrahman and Akl, Mohammed A and Robaian, Ali and Althubaitiy, Ramzi and Alnasser, Abdullah and Anadioti, Evanthia},
  title = {Comparative accuracy of digital impressions using universal dual‐purpose scan jigs for maxillary implant full arch impressions: An in vitro study},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.14029}
}
Kostenlos starten →