Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions: An In Vitro Comparative Study
Clinical Oral Implants Research · 2026
DOI: 10.1111/clr.70161 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, 2026. Verfasst von Reo Ikumi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Implant Society of Japan, Toshima-ku, Japan. Hauptthemen laut MEDLINE: Dental Impression Technique, Computer-Aided Design, Dental Implants. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objectives
To compare four complete‐arch implant impression workflows—segmented right/left IOS merged via a palatal marker (IOS‐LEGO‐Seg), continuous full‐arch IOS with a palatal marker (IOS‐LEGO‐Full), continuous full‐arch IOS without a palatal marker (IOS‐Full), and a conventional open‐tray PVS impression followed by cast fabrication and cast scanning (CI)—and to evaluate whether segmentation combined with a palatal marker improves agreement with a laboratory reference dataset in a maxillary edentulous model. Material and Methods A maxillary edentulous dental cast with six implants was used to compare IOS‐LEGO‐Seg, IOS‐LEGO‐Full, IOS‐Full, and CI. Intraoral scans were acquired, with 10 repetitions per condition. Datasets were superimposed onto a master reference scan using three alveolar‐ridge markers; the palatal marker was excluded. The primary outcome was the concordance rate, defined as the proportion of intraoral scan body surface points within ±50 μm of the reference. A linear mixed‐effects model was used to compare workflows ( α = 0.05).
Results
IOS‐LEGO‐Seg achieved the highest concordance, followed by IOS‐LEGO‐Full, IOS‐Full, and CI ( p < 0.001). The concordance rate was comparable between the IOS‐LEGO‐Full and IOS‐Full groups, indicating that the addition of a palatal marker alone did not improve accuracy. Site‐specific analysis revealed lower concordance at the distal molars (#16 and #26) in the non‐segmented IOS workflows; however, this effect was mitigated by the segmented approach. The CI group did not show site‐specific differences.
Conclusions
The segmented workflow with a palatal marker may represent an accessible strategy for improving the accuracy of maxillary complete‐arch implant impressions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Implant Society of Japan, Toshima-ku, Japan.
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.
ORCID-Profile: Reo Ikumi, Takahiro Murakami, Luís Azevedo, João Pitta, Duygu Karasan, Irena Sailer
Zitieren
APA
Ikumi, R., Murakami, T., Azevedo, L., Pitta, J., Karasan, D., & Sailer, I. (2026). Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions: An In Vitro Comparative Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70161
Vancouver
Ikumi R, Murakami T, Azevedo L, Pitta J, Karasan D, Sailer I. Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions: An In Vitro Comparative Study. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70161
BibTeX
@article{Ikumi2026,
author = {Ikumi, Reo and Murakami, Takahiro and Azevedo, Luís and Pitta, João and Karasan, Duygu and Sailer, Irena},
title = {Segmented Intraoral Scanning With a Palatal Marker for Complete‐Arch Digital Implant Impressions: An In Vitro Comparative Study},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70161}
}
EUVIMED