Tooth‐Supported 3D ‐Printed Surgical Guide for Titanium Mesh Placement in Bone Augmentation of the Esthetic Zone
Journal of Esthetic and Restorative Dentistry · 2026
DOI: 10.1111/jerd.70063 ↗At a glance
Journal article in Journal of Esthetic and Restorative Dentistry, 2026. Written by Geru Zhang and 3 co-authors. Institution: State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, C…. Major MEDLINE topics: Printing, Three-Dimensional, Titanium, Surgical Mesh, Esthetics, Dental. Cited 2 times so far (Crossref); 32 references. Funded by: Exploration and R&D Project of West China Hospital of Stomatology.
Abstract (original language)
Objective
To describe a tooth‐supported, 3D‐printed surgical guide designed to enable accurate intraoperative placement of titanium mesh for bone augmentation in the esthetic zone, in accordance with the preoperative design. Clinical Consideration Titanium mesh supported guided bone regeneration (GBR) is a widely accepted technique for bone augmentation due to its strong spatial support and predictable osteogenesis. However, intraoperative deviations in titanium mesh placement may affect the final outcome of bone augmentation. This case series presents a tooth‐supported titanium mesh positioning guide, fabricated through personalized 3D printing, which allows in situ fixation of the mesh during the augmentation procedure.
Conclusion
The guide enabled precise intraoperative positioning of the titanium mesh in accordance with the preoperative design. The maximum intraoperative titanium mesh displacement was 1.59 mm, with an average deviation of 0.42 mm. The average overall bone augmentation volume deviation was 0.057 ± 0.031 cm 3 (SD), 95% CI: (0.025 cm 3 , 0.089cm 3 ), corresponding to a bone augmentation accuracy of 91.67%. Clinical Significance This tooth‐supported positioning guide accurately transfers the preoperative design to titanium mesh‐supported guided bone regeneration surgery, thereby improving the accuracy of titanium mesh placement. It facilitates a standardized and controlled workflow for bone augmentation, enhancing the predictability of outcomes in the esthetic zone.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, P. R. China.
- Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
ORCID profiles: Xiaoxiao Cai
Funding
- Exploration and R&D Project of West China Hospital of Stomatology
Cite
APA
Zhang, G., Huang, L., Gao, Y., & Cai, X. (2026). Tooth‐Supported 3D ‐Printed Surgical Guide for Titanium Mesh Placement in Bone Augmentation of the Esthetic Zone. Journal of Esthetic and Restorative Dentistry. https://doi.org/10.1111/jerd.70063
Vancouver
Zhang G, Huang L, Gao Y, Cai X. Tooth‐Supported 3D ‐Printed Surgical Guide for Titanium Mesh Placement in Bone Augmentation of the Esthetic Zone. Journal of Esthetic and Restorative Dentistry. 2026. doi:10.1111/jerd.70063
BibTeX
@article{Zhang2026,
author = {Zhang, Geru and Huang, Liwei and Gao, Yang and Cai, Xiaoxiao},
title = {Tooth‐Supported 3D ‐Printed Surgical Guide for Titanium Mesh Placement in Bone Augmentation of the Esthetic Zone},
journal = {Journal of Esthetic and Restorative Dentistry},
year = {2026},
doi = {10.1111/jerd.70063}
}