Leadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safety
Journal of Interventional Cardiac Electrophysiology · 2024
DOI: 10.1007/s10840-024-01796-w ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Enes Elvin Gul und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Electrophysiology, Istanbul Atlas University Medicine Hospital, Istanbul, Turkey. elvin_salamov@yahoo.com. Hauptthemen laut MEDLINE: Feasibility Studies, Pacemaker, Artificial, Tricuspid Valve, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Permanent pacing is often required following valve intervention (either surgical or percutaneous); however, tricuspid interventions pose specific challenges to conventional pacing. Therefore, leadless pacemaker (LP) implantation may be the preferred strategy when permanent pacing is required after tricuspid valve intervention. PURPOSE: To report periprocedural outcomes and follow-up of patients undergoing implantation of a LP system following tricuspid valve interventions. METHODS: Patients with previous tricuspid valve intervention at the time of attempted implantation of a LP (MicraTM, Medtronic, Minneapolis, MN, USA) were included. RESULTS: Between 2019 and 2022, 40 patients underwent LP implantations following tricuspid interventions in 5 large tertiary centers. The mean age was 68.9 ± 13.7 years, and 48% patients were male. The indication for pacing was as following: AVB in 27 (68%) patients, AF with slow ventricular response in 10 (25%) patients, and refractory rapid atrial fibrillation (AF) referred to AV junction ablation in 3 (7%) patients. Most of the patients received Micra VR (78%). The procedure was successful in all patients. The mean procedural time is 58 ± 32 min, and the median fluoroscopy time is 7.5 min. Electrical parameters were within normal range (threshold: 1.35 ± 1.2 V@0.24 ms, impedance: 772 ± 245 Ohm, R-wave: 6.9 ± 5.4 mV). No acute complications were observed. During a mean follow-up of 10 months, electrical parameters remained stable, and 4 deaths were occurred (not related to the procedure). CONCLUSION: A LP is a safe and efficient option following tricuspid valve interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiac Electrophysiology, Istanbul Atlas University Medicine Hospital, Istanbul, Turkey. elvin_salamov@yahoo.com.
- European Hospital Georges Pompidou, Paris, France.
- The Olga and Lev Leviev Heart Center, The Chaim Sheba Medical Center, Tel Aviv, Israel.
- Le Millénaire Private Hospital, Montpellier, France.
- Trousseau University Hospital Centre, Tours, France.
- Electrophysiology Unit, Department of Cardiology, Caen University Hospital, Avenue de La Côte de Nacre, 14000, Caen, France.
Zitieren
APA
Gul, E. E., Baudinaud, P., Waldmann, V., Sabbag, A., Jubeh, Y., Clementy, N., Bisson, A., Ollitrault, P., Conti, S., Carabelli, A., & Dogan, Z. (2024). Leadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safety. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01796-w
Vancouver
Gul EE, Baudinaud P, Waldmann V, Sabbag A, Jubeh Y, Clementy N, et al. Leadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safety. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01796-w
BibTeX
@article{Gul2024,
author = {Gul, Enes Elvin and Baudinaud, Pierre and Waldmann, Victor and Sabbag, Avi and Jubeh, Yousef and Clementy, Nicholas and Bisson, Arnaud and Ollitrault, Pierre and Conti, Sergio and Carabelli, Adrian and Dogan, Zeki},
title = {Leadless pacemaker implantation following tricuspid interventions: multicenter collaboration of feasibility and safety},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01796-w}
}
EUVIMED