Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation

Jieruo Chen, Zefeng Wang, Fei Hang, Weiping Sun, Haiwei Li, Yongquan Wu

Clinical Cardiology · 2025

DOI: 10.1002/clc.70116 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Cardiology, 2025. Verfasst von Jieruo Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cardiac Pacing, Artificial, Heart Ventricles, Pacemaker, Artificial. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research received funding from the Clinical Technology Innovation Project of Beijing Hospital Management Center..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Traditional right ventricular pacing (RVP) can lead to asynchronous cardiac mechanical contractions and increase the risk of atrial fibrillation (AF). This study aimed to compare the occurrence of new‐onset AF and the progression of AF between novel physiological pacing—left bundle branch area pacing (LBBAP) and RVP with a long‐term follow‐up. Methods and Results Patients with a dual‐chamber permanent pacemaker initial implantation, no history of persistent AF, and an expected high proportion of ventricular pacing (VP ≥ 20%) were included in this retrospective cohort study (LBBAP, n = 122; RVP, n = 166). The pacing QRS duration (QRSd) of the LBBAP was significantly shorter than that of the RVP (113 ± 22 vs. 140 ± 27 ms, p < 0.001), while the intrinsic QRSd values from the two groups were comparable. During a mean follow‐up of 21.9 ± 9.4 months, the composite outcome of postoperative new‐onset AF or AF progression was higher in the RVP group than in the LBBAP group (RVP HR 2.62, 95%CI 1.21–5.67, p = 0.014). Left ventricular end‐diastolic diameter (LVEDD) levels decreased in the LBBAP group at 1 year follow‐up (50 ± 6 vs. baseline 48 ± 6, p = 0.002).

Conclusions

In a mean follow‐up period of 2 years, compared to RVP, LBBAP patients with VP ≥ 20% had a decreased risk of occurrence and progression of AF events.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCardiac Pacing, ArtificialHeart VentriclesPacemaker, ArtificialBundle of HisVentricular Function, RightHeart RateHumansMaleFemaleRetrospective StudiesAgedTime FactorsFollow-Up StudiesTreatment OutcomeElectrocardiographyMiddle AgedRisk FactorsDisease Progression

Stichwörter der Autor:innen

atrial fibrillationdual‐chamber permanent pacemakerleft bundle branch area pacingpacingphysiological pacing

Autor:innen und Institutionen

  • Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Förderung

  • This research received funding from the Clinical Technology Innovation Project of Beijing Hospital Management Center.

Zitieren

APA

Chen, J., Wang, Z., Hang, F., Sun, W., Li, H., & Wu, Y. (2025). Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation. Clinical Cardiology. https://doi.org/10.1002/clc.70116

Vancouver

Chen J, Wang Z, Hang F, Sun W, Li H, Wu Y. Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation. Clinical Cardiology. 2025. doi:10.1002/clc.70116

BibTeX
@article{Chen2025,
  author = {Chen, Jieruo and Wang, Zefeng and Hang, Fei and Sun, Weiping and Li, Haiwei and Wu, Yongquan},
  title = {Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation},
  journal = {Clinical Cardiology},
  year = {2025},
  doi = {10.1002/clc.70116}
}
Kostenlos starten →