Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices
Heart and Vessels · 2024
DOI: 10.1007/s00380-024-02409-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart and Vessels, 2024. Verfasst von Yoshiyasu Aizawa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Nippon Medical School Hospital, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan. yoshiyasu612@gmail.com. Hauptthemen laut MEDLINE: Atrial Fibrillation, Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Asymptomatic paroxysmal atrial fibrillation (AF) is often found in patients implanted with cardiac implantable electronic devices (CIEDs). Second-generation atrial antitachycardia pacing (A-ATP) is effective in managing AF in patients implanted with CIEDs. The purpose of this study was to evaluate the efficacy and safety of A-ATP in patients implanted with CIEDs. This was a single-center retrospective study involving 91 patients (male 46 patients, mean age 74 ± 9 years) implanted with Reactive A-ATP equipped devices (84 patients with pacemakers, 6 with ICDs, and 1 with a CRT-D). The AF burden, rate of AF termination, and details of the activation of the A-ATP were analyzed in each patient. During a mean follow-up period of 21 ± 13 months, A-ATP was activated in 45 of 91 patients (49.5%). No patients had adverse events. Although the efficacy of the A-ATP varied among the patients, the median rate of AF termination was 44%. In comparison to the A-ATP start time, “0 min” had a higher AF termination rate by the A-ATP (39.4% vs. 24.4%, P = 0.011). The rate of termination by the A-ATP was high for AF with a long cycle length and a relatively regular rhythm. A-ATP successfully terminated AF episodes in some patients implanted with CIEDs. The optimal settings of the A-ATP will be determined in future studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Nippon Medical School Hospital, 1-1-5, Sendagi, Bunkyo-ku, Tokyo, 113-8603, Japan. yoshiyasu612@gmail.com.
- Komura Cardiovascular Clinic, Saitama, Japan.
- Department of Cardiology, Saiseikai Kawaguchi General Hospital, Saitama, Japan.
Zitieren
APA
Aizawa, Y., Komura, S., Kawakami, E., Watanabe, S., Tanaka, K., Kadowaki, H., & Takagi, A. (2024). Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices. Heart and Vessels. https://doi.org/10.1007/s00380-024-02409-2
Vancouver
Aizawa Y, Komura S, Kawakami E, Watanabe S, Tanaka K, Kadowaki H, et al. Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices. Heart and Vessels. 2024. doi:10.1007/s00380-024-02409-2
BibTeX
@article{Aizawa2024,
author = {Aizawa, Yoshiyasu and Komura, Satoru and Kawakami, Emiko and Watanabe, Shonosuke and Tanaka, Kazuki and Kadowaki, Hiromu and Takagi, Atsushi},
title = {Characteristics of successful termination of atrial fibrillation by atrial antitachycardia pacing in patients with cardiac implantable electronic devices},
journal = {Heart and Vessels},
year = {2024},
doi = {10.1007/s00380-024-02409-2}
}
EUVIMED