Lesion Depth Optimization in High‐Power Radiofrequency Ablation: Evaluating Single High‐Power and Combined Very High‐Power Applications

Hidehiro Iwakawa iD, Masateru Takigawa iD, Ryosuke Kato, Junji Yamaguchi, Masaki Honda, Ryo Tateishi, Miho Negishi, Iwanari Kawamura, Kentaro Goto, Takuro Nishimura, Kazuya Yamao, Susumu Tao and 5 more

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.70125 ↗

At a glance

Vergleichsstudie in Journal of Cardiovascular Electrophysiology, 2025. Written by Hidehiro Iwakawa and 16 co-authors. Institution: Department of Cardiovascular Medicine, Institute of Science Tokyo, Tokyo, Japan. Major MEDLINE topics: Catheter Ablation, Myocardium. 25 references. The full text is freely available in PubMed Central. Funded by: This study was supported by the Biosense Webster, Inc through the investigator-initiated study program IIS-648, and Japan Society for the Promotion of Science,…, Japan Society for the Promotion of Science.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

A very high‐power short‐duration (vHPSD) radiofrequency (RF) ablation creates shallower lesions, which may be insufficient in thick myocardial regions.

Aims

To clarify an effective ablation strategy following the initial vHPSD application and determine the best approach to create sufficient lesion depth in thick myocardial regions using ex vivo and in vivo models.

Methods

Lesion metrics were compared under various settings: 35 W versus 50 W with the same target ablation index (AI) (Step 1); double vHPSD ablations versus vHPSD followed by AI‐guided ablation (Step 2); double applications (DA) with vHPSD followed by AI‐guided ablation with a target AI of 450 versus single application (SA) with a target AI of 550 at 50 W (Step 3).

Results

Lesion depth was comparable between groups with the same AI but different RF powers. Lesions were significantly deeper in the vHPSD ablation followed by a target AI of 450 compared to double vHPSD ablations (vHPSD + vHPSD, 3.4 [3.1–3.6] mm; vHPSD + AI 450 at 35 W, 4.4 [4.1–4.9] mm; vHPSD + AI 450 at 50 W, 4.5 [4.1–4.9] mm, p < 0.001). High‐power SA with a target AI of 550 created significantly deeper lesions than vHPSD + AI 450 (DA vs. SA, 4.5 [3.5–5.3] mm vs. 5.0 [4.1–5.9] mm, p = 0.01).

Conclusions

AI‐guided RF applications following vHPSD effectively increased lesion depth more than repeated vHPSD. However, a single high‐power application targeting a higher AI resulted in the deepest lesions. This strategy may be particularly beneficial in thick atrial myocardial regions to enhance lesion durability and improve procedural outcomes.

Subjects

MeSH terms (MEDLINE)

Catheter AblationMyocardiumAnimalsSwineTime FactorsAction Potentials

Author keywords

QDOT MICROcatheter ablationex vivoin vivolesion sizevery high‐power short‐duration

Authors and institutions

  • Department of Cardiovascular Medicine, Institute of Science Tokyo, Tokyo, Japan.
  • Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan.
  • Division of Advanced Arrhythmia Research, Institute of Science Tokyo, Tokyo, Japan.
  • Department of Clinical and Diagnostic Laboratory Science, Institute of Science Tokyo, Tokyo, Japan.
  • Japan Small Animal Medical Center, Saitama, Japan.
  • Center for Experimental Animals, Institute of Science Tokyo, Tokyo, Japan.

ORCID profiles: Hidehiro Iwakawa, Masateru Takigawa, Tetsuo Sasano

Funding

  • This study was supported by the Biosense Webster, Inc through the investigator-initiated study program IIS-648, and Japan Society for the Promotion of Science,…
  • Japan Society for the Promotion of Science

Cite

APA

Iwakawa, H., Takigawa, M., Kato, R., Yamaguchi, J., Honda, M., Tateishi, R., Negishi, M., Kawamura, I., Goto, K., Nishimura, T., Yamao, K., Tao, S., Suzuki, S., Iwanaga, T., Miyazaki, S., Watanabe, H., & Sasano, T. (2025). Lesion Depth Optimization in High‐Power Radiofrequency Ablation: Evaluating Single High‐Power and Combined Very High‐Power Applications. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70125

Vancouver

Iwakawa H, Takigawa M, Kato R, Yamaguchi J, Honda M, Tateishi R, et al. Lesion Depth Optimization in High‐Power Radiofrequency Ablation: Evaluating Single High‐Power and Combined Very High‐Power Applications. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70125

BibTeX
@article{Iwakawa2025,
  author = {Iwakawa, Hidehiro and Takigawa, Masateru and Kato, Ryosuke and Yamaguchi, Junji and Honda, Masaki and Tateishi, Ryo and Negishi, Miho and Kawamura, Iwanari and Goto, Kentaro and Nishimura, Takuro and Yamao, Kazuya and Tao, Susumu and Suzuki, Sayaka and Iwanaga, Takehiro and Miyazaki, Shinsuke and Watanabe, Hiroyuki and Sasano, Tetsuo},
  title = {Lesion Depth Optimization in High‐Power Radiofrequency Ablation: Evaluating Single High‐Power and Combined Very High‐Power Applications},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.70125}
}
Start for free →