Coronary Sinus Venoplasty Using Cutting Balloon for Left Ventricular Lead Placement
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16765 ↗At a glance
Journal article in Journal of Cardiovascular Electrophysiology, 2025. Written by Pooja Shah and 3 co-authors. Institution: Department of Cardiology, Epic hospital, Ahmedabad, Gujarat, India. Major MEDLINE topics: Coronary Sinus, Cardiac Resynchronization Therapy Devices, Cardiac Resynchronization Therapy, Angioplasty, Balloon, Coronary. 14 references.
Abstract (original language)
Background
Coronary Sinus Venous stenosis is rare; however, it is often encountered during left ventricular (LV) lead implantation, which is the cornerstone of cardiac resynchronization therapy (CRT). Plain balloon angioplasty and anchor balloon technique have been described for LV lead implantation in patients with venous stenosis and tortuous anatomy. We investigate the efficacy of coronary vein angioplasty using a cutting balloon to facilitate the implantation of LV lead.
Methods
452 patients who underwent standard CRT implantation from 2015 to 2024 were studied retrospectively. 21 patients (4.64%) had significant venous stenosis in the posterolateral vein, which required venous intervention to facilitate lead placement. Seven patients required cutting balloon dilatation for focal venous stenosis in which balloon dilation and anchor balloon technique failed.
Results
All seven patients had successful LV lead implantation in the target vein following cutting balloon venoplasty. There was no complication during the procedure and long‐term lead parameters were excellent.
Conclusion
Coronary vein angioplasty using a cutting balloon is an effective and safe technique to facilitate LV pacing lead placement in case of target vein stenoses.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Epic hospital, Ahmedabad, Gujarat, India.
- Department of Life sciences, Ahmedabad University, Ahmedabad, Gujarat, India.
- Department of Cardiology, Zydus Hospital, Ahmedabad, Gujarat, India.
- Department of Cardiology, Epic Hospital, Ahmedabad, Gujarat, India.
ORCID profiles: Anoop K Gupta
Cite
APA
Shah, P., Gupta, J., Yadav, N., & Gupta, A. K. (2025). Coronary Sinus Venoplasty Using Cutting Balloon for Left Ventricular Lead Placement. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16765
Vancouver
Shah P, Gupta J, Yadav N, Gupta AK. Coronary Sinus Venoplasty Using Cutting Balloon for Left Ventricular Lead Placement. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16765
BibTeX
@article{Shah2025,
author = {Shah, Pooja and Gupta, Jyotika and Yadav, Niraj and Gupta, Anoop K},
title = {Coronary Sinus Venoplasty Using Cutting Balloon for Left Ventricular Lead Placement},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16765}
}
EUVIMED