Challenging coronary sinus lead placement for CRT: A modified “Anchoring balloon” technique
Pacing and Clinical Electrophysiology · 2024
DOI: 10.1111/pace.14869 ↗Kurz gefasst
Fallbericht in der Zeitschrift Pacing and Clinical Electrophysiology, 2024. Verfasst von Ronpichai Chokesuwattanaskul und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Faculty of Medicine, Cardiac Center, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Thai Red Cross Society, …. Hauptthemen laut MEDLINE: Coronary Sinus, Cardiac Resynchronization Therapy. Die Arbeit nennt 7 Literaturangaben.
Abstract (Originalsprache)
An 80‐year‐old man with a history of complete heart block underwent dual chamber pacemaker implantation about a year ago. He returned to the hospital due to de novo heart failure caused by pacing‐induced cardiomyopathy; hence, we planned to upgrade his pacemaker to a biventricular device. The initial strategy was to perform left bundle branch area pacing‐optimized cardiac resynchronization therapy (LOT‐CRT) with left bundle branch area pacing (LBBAP) combined with a coronary sinus (CS) lead. In this challenging case, the successful placement of a CS lead was hindered by a complicated combination of a large CS body linked to the left superior vena cava and a winding CS branch. However, utilizing readily available tools, such as the coronary balloon and Guide Plus II ST catheter, proved instrumental in overcoming these obstacles. As a result, LOT‐CRT provided the patient with a safe alternative to surgical LV lead placement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medicine, Faculty of Medicine, Cardiac Center, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Thai Red Cross Society, Bangkok, Thailand.
- Department of Medicine, Faculty of Medicine, Center of Excellence in Arrhythmia Research Chulalongkorn University, Chulalongkorn University, Bangkok, Thailand.
- Division of Cardiovascular Medicine, Frankel Cardiovascular Center, University of Michigan Health, Ann Arbor, Michigan, USA.
ORCID-Profile: Ronpichai Chokesuwattanaskul, Nithi Tokavanich
Zitieren
APA
Chokesuwattanaskul, R., Tokavanich, N., & Srimahachota, S. (2024). Challenging coronary sinus lead placement for CRT: A modified “Anchoring balloon” technique. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14869
Vancouver
Chokesuwattanaskul R, Tokavanich N, Srimahachota S. Challenging coronary sinus lead placement for CRT: A modified “Anchoring balloon” technique. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.14869
BibTeX
@article{Chokesuwattanaskul2024,
author = {Chokesuwattanaskul, Ronpichai and Tokavanich, Nithi and Srimahachota, Suphot},
title = {Challenging coronary sinus lead placement for CRT: A modified “Anchoring balloon” technique},
journal = {Pacing and Clinical Electrophysiology},
year = {2024},
doi = {10.1111/pace.14869}
}
EUVIMED