Predictive Role of Intraoperative Impedance in Midterm Pacing Threshold Elevation: Insights From Aveir VR Leadless Pacemaker Implantations
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.16639 ↗At a glance
Multizentrische Studie in Journal of Cardiovascular Electrophysiology, 2025. Written by Takehiro Nomura and 7 co-authors. Institution: Heart Rhythm Center, Department of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Miyagi, Japan. Major MEDLINE topics: Pacemaker, Artificial, Bradycardia, Cardiac Pacing, Artificial, Heart Rate. Cited 7 times so far (Crossref); 19 references. Funded by: The authors received no specific funding for this work..
Abstract (original language)
Introduction
Leadless pacemakers (LPs) are a valuable treatment for bradycardia, with the Aveir offering advanced features, including a protective sleeve and active fixation. This study investigated the intraoperative factors during Aveir VR implantations that predict midterm pacing capture threshold (PCT) elevations and proposed strategies for optimizing the outcomes. Methods and Results This retrospective study included 67 patients who underwent Aveir VR implantations in two Japanese facilities between March and June 2023, with a 360‐day follow‐up. The impedance and PCT were measured three times during the procedure (premapping, during the tether mode, and at the end of the procedure). A PCT elevation was defined as that > 1.5 V/0.4 ms during follow‐up. PCT elevations were observed in 7 patients (10.4%), all with sinus node dysfunction. The impedance during the tether mode (Imp te ) and end of the procedure (Imp end ) was significantly lower in patients with a PCT elevation ( p < 0.001). The receiver operating characteristic curve analysis demonstrated that the Imp te (AUC: 0.868) and Imp end (AUC: 0.857) effectively predicted PCT elevations, with a cutoff of > 380 Ω associated with a lower incidence of PCT elevations. For the Imp te , the sensitivity was 85.7% and specificity 90.0%. Moreover, a high impedance during premapping (AUC: 0.892) predicted an Imp te > 380 Ω, and when the premapping impedance was > 430 Ω, all cases had an Imp te > 380 Ω. The median number of days until the PCT elevation was 40 (range: 1–321 days), and in 3 out of 7 patients, PCT elevations were observed more than 270 days after the implantation.
Conclusion
The higher impedance during the implantation was a strong predictor of a midterm favorable PCT. Those findings highlighted the potential for impedance‐guided strategies to optimize implantations and output settings. The occurrence of PCT elevations beyond 270 days underscored the need for long‐term monitoring and individualized follow‐up strategies. Further studies are needed to validate these findings and explore their clinical impact.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Heart Rhythm Center, Department of Cardiovascular Medicine, Sendai Kosei Hospital, Sendai, Miyagi, Japan.
- Department of Cardiovascular Medicine, School of Medicine, Dokkyo Medical University, Shimotsuga-gun, Tochigi, Japan.
- Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Fukuoka, Japan.
ORCID profiles: Takehiro Nomura, Kennosuke Yamashita
Funding
- The authors received no specific funding for this work.
Cite
APA
Nomura, T., Yamashita, K., Nagashima, M., Kuji, R., Mizuno, Y., Kumazawa, D., Onodera, K., & Ando, K. (2025). Predictive Role of Intraoperative Impedance in Midterm Pacing Threshold Elevation: Insights From Aveir VR Leadless Pacemaker Implantations. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16639
Vancouver
Nomura T, Yamashita K, Nagashima M, Kuji R, Mizuno Y, Kumazawa D, et al. Predictive Role of Intraoperative Impedance in Midterm Pacing Threshold Elevation: Insights From Aveir VR Leadless Pacemaker Implantations. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16639
BibTeX
@article{Nomura2025,
author = {Nomura, Takehiro and Yamashita, Kennosuke and Nagashima, Michio and Kuji, Rei and Mizuno, Yosuke and Kumazawa, Daiki and Onodera, Kosuke and Ando, Kenji},
title = {Predictive Role of Intraoperative Impedance in Midterm Pacing Threshold Elevation: Insights From Aveir VR Leadless Pacemaker Implantations},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.16639}
}
EUVIMED