Computed Tomography‐Verified Pacing Location of Micra Leadless Pacemakers and Characteristics of Paced Electrocardiograms in Bradycardia Patients

Jianghua Zhang, Xianhui Zhou iD, Yanmei Lu iD, Yaodong Li iD, Qiang Xing, Zukela Tuerhong, Xu Yang, Jiasuoer Xiaokereti, Yankai Guo, Xiaohong Zhou, Samantha Kohnle, Siyuan Zou und 1 weitere

Clinical Cardiology · 2025

DOI: 10.1002/clc.70209 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Cardiology, 2025. Verfasst von Jianghua Zhang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Pacing and Electrophysiology Department, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China. Hauptthemen laut MEDLINE: Bradycardia, Electrocardiography, Pacemaker, Artificial, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This study was supported by Natural Science Foundation of Xinjiang Uygur Autonomous Region (Grant number 2022D01C486)..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The leadless pacemakers are implanted routinely under fluoroscopic image, yet the pacing sites and corresponding paced electrocardiography (ECG) remain unclear. This study was to determine the computed tomography (CT)‐verified location of the leadless Micra pacemakers (Micra) and ECG characteristics.

Methods

Twenty consecutive patients who met the pacemaker indications for bradycardia and underwent fluoroscopy assisted Micra implantation were enrolled. All subjects underwent a postoperative CT scan to determine the precise location of the Micra pacing tip. Paced 12‐lead ECG characteristics were analysed and correlated with the Micra tip location.

Results

In the nine partitions of fluoroscopic RAO images, 14 (70%) of 20 patients had the Micra tip in zone 5, 5 (25%) in zone 6 and 1 in zone 2. Reconstructed CT 3‐D cardiac images found Micra tips mostly clustered near the anterior insertion between the RV septum and free wall with 12 cases at the insertion‐septal side and 8 at the free‐wall side. ECG morphological analysis found that the peak deflection index in ECG lead V1 was 0.409 ± 0.058 for Micra tips at the insertion‐septal side and 0.527 ± 0.062 in the free‐wall side ( p < 0.001 between two sides) and R wave amplitude in lead V6 appeared larger for Micra tips in the free‐wall group compared to Micra tips in the insertion‐septal group, while there was no difference in QRS duration between two sides.

Conclusion

In routine Micra implantation, the pacing sites were often located in the anterior insertion region.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BradycardiaElectrocardiographyPacemaker, ArtificialCardiac Pacing, ArtificialTomography, X-Ray ComputedHeart RateHumansMaleFemaleAgedMiddle AgedFluoroscopyEquipment DesignAged, 80 and overRetrospective StudiesTreatment OutcomePredictive Value of Tests

Stichwörter der Autor:innen

bradycardiacardiac computed tomographyleadless pacemakerright ventricular septum

Autor:innen und Institutionen

  • Cardiac Pacing and Electrophysiology Department, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China.
  • Xinjiang Key Laboratory of Cardiac Electrophysiology and Cardiac Remodelling, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China.
  • Research and Technology Division, Cardiac Rhythm Management, Medtronic Inc., Minneapolis, Minnesota, USA.
  • Cardiac Rhythm Management, Medtronic (Shanghai), Shanghai, China.

ORCID-Profile: Xianhui Zhou, Yanmei Lu, Yaodong Li, Baopeng Tang

Förderung

  • This study was supported by Natural Science Foundation of Xinjiang Uygur Autonomous Region (Grant number 2022D01C486).

Zitieren

APA

Zhang, J., Zhou, X., Lu, Y., Li, Y., Xing, Q., Tuerhong, Z., Yang, X., Xiaokereti, J., Guo, Y., Zhou, X., Kohnle, S., Zou, S., & Tang, B. (2025). Computed Tomography‐Verified Pacing Location of Micra Leadless Pacemakers and Characteristics of Paced Electrocardiograms in Bradycardia Patients. Clinical Cardiology. https://doi.org/10.1002/clc.70209

Vancouver

Zhang J, Zhou X, Lu Y, Li Y, Xing Q, Tuerhong Z, et al. Computed Tomography‐Verified Pacing Location of Micra Leadless Pacemakers and Characteristics of Paced Electrocardiograms in Bradycardia Patients. Clinical Cardiology. 2025. doi:10.1002/clc.70209

BibTeX
@article{Zhang2025,
  author = {Zhang, Jianghua and Zhou, Xianhui and Lu, Yanmei and Li, Yaodong and Xing, Qiang and Tuerhong, Zukela and Yang, Xu and Xiaokereti, Jiasuoer and Guo, Yankai and Zhou, Xiaohong and Kohnle, Samantha and Zou, Siyuan and Tang, Baopeng},
  title = {Computed Tomography‐Verified Pacing Location of Micra Leadless Pacemakers and Characteristics of Paced Electrocardiograms in Bradycardia Patients},
  journal = {Clinical Cardiology},
  year = {2025},
  doi = {10.1002/clc.70209}
}
Kostenlos starten →