Characteristics of tissue temperature during ablation with THERMOCOOL SMARTTOUCH SF versus TactiCath versus QDOT MICRO catheters (Qmode and Qmode+): An in vivo porcine study
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16092 ↗At a glance
Journal article in Journal of Cardiovascular Electrophysiology, 2024. Written by Naoto Otsuka and 9 co-authors. Institution: Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan. Major MEDLINE topics: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins. Cited 12 times so far (Crossref); 29 references. Funded by: Biosense Webster, Inc..
Abstract (original language)
Introduction
High‐power short‐duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear.
Methods
In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W‐HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s‐vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters.
Results
STSF produced the highest maximum tissue temperature (T max ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t−T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip‐to‐thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t−T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with T max .
Conclusion
This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on T max and/or t−T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan.
- Medical Research Support Center, Institute of Medical Science, Section of Laboratory for Animal Experiments, Nihon University School of Medicine, Tokyo, Japan.
ORCID profiles: Naoto Otsuka, Koichi Nagashima, Yuji Wakamatsu, Satoshi Hayashida, Toshiko Nakai
Funding
- Biosense Webster, Inc.
Cite
APA
Otsuka, N., Okumura, Y., Kuorkawa, S., Nagashima, K., Wakamatsu, Y., Hayashida, S., Ohkubo, K., Nakai, T., Takahashi, R., & Taniguchi, Y. (2024). Characteristics of tissue temperature during ablation with THERMOCOOL SMARTTOUCH SF versus TactiCath versus QDOT MICRO catheters (Qmode and Qmode+): An in vivo porcine study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16092
Vancouver
Otsuka N, Okumura Y, Kuorkawa S, Nagashima K, Wakamatsu Y, Hayashida S, et al. Characteristics of tissue temperature during ablation with THERMOCOOL SMARTTOUCH SF versus TactiCath versus QDOT MICRO catheters (Qmode and Qmode+): An in vivo porcine study. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16092
BibTeX
@article{Otsuka2024,
author = {Otsuka, Naoto and Okumura, Yasuo and Kuorkawa, Sayaka and Nagashima, Koichi and Wakamatsu, Yuji and Hayashida, Satoshi and Ohkubo, Kimie and Nakai, Toshiko and Takahashi, Rie and Taniguchi, Yoshiki},
title = {Characteristics of tissue temperature during ablation with THERMOCOOL SMARTTOUCH SF versus TactiCath versus QDOT MICRO catheters (Qmode and Qmode+): An in vivo porcine study},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16092}
}
EUVIMED