‘Single-shot’ pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy
Europace · 2023
DOI: 10.1093/europace/euad362 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2023. Verfasst von Sijia Pu und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, South China University of Technology, Guangzhou, China. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 10-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Insight Medtech Co., Ltd.
Abstract (Originalsprache)
Aims
Pulsed field ablation (PFA) is emerging as a non-thermal, tissue-specific technique for pulmonary vein isolation (PVI) in atrial fibrillation therapy. This pre-clinical study aims to investigate the feasibility and safety of PVI using a novel PFA system including a nanosecond-scale PFA generator, a novel lotos PFA catheter, and a customized 12 Fr steerable sheath. Methods and results A total of 11 Yorkshire swine were included in this study, with 4 in the acute cohort and 7 in the chronic cohort. Under general anaesthesia, transseptal puncture and pulmonary vein (PV) angiography was initially performed. The PFA catheter was navigated to position at the right and left PV antrum after the electroanatomic reconstruction of the left atrium. Biphasic PFA applications were performed on PVs in both the spindle-shaped and the lotos-shaped poses. Pulmonary vein isolation and PFA-associated safety were assessed 30 min after ablation in both cohorts and 30 days later in the chronic cohort. Detailed necropsy and histopathology were performed. Additional intracardiac echocardiography and coronary angiogram were evaluated for safety. All target PVs (n = 20) were successfully isolated on the first attempt. No spasm of coronary artery or microbubble was seen during the procedure. Eleven of 12 PVs (91.6%) remained in isolation at the 30-day invasive study. No evidence of PV stenosis was observed in any targets. However, transient diaphragm capture occurred in 17.6%. Histopathological examinations showed no evidence of collateral injury.
Conclusion
This study provides scientific evidence demonstrating the safety and efficacy of the novel PFA catheter and system for single-shot PVI, which shows great potential.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, South China University of Technology, Guangzhou, China.
- Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 106 Zhongshan Er Rd, Guangzhou 510080, China.
- Insight Medtech Co., Ltd, Shenzhen, China.
ORCID-Profile: Sijia Pu, Fangzhou Liu, Yumei Xue, Weidong Lin
Förderung
- Insight Medtech Co., Ltd
Zitieren
APA
Pu, S., Liu, F., Chen, Y., Luo, C., Li, P., Chen, Y., Fu, L., Liu, H., Ye, X., Wu, S., Xue, Y., & Lin, W. (2023). ‘Single-shot’ pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy. Europace. https://doi.org/10.1093/europace/euad362
Vancouver
Pu S, Liu F, Chen Y, Luo C, Li P, Chen Y, et al. ‘Single-shot’ pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy. Europace. 2023. doi:10.1093/europace/euad362
BibTeX
@article{Pu2023,
author = {Pu, Sijia and Liu, Fangzhou and Chen, Yuhan and Luo, Cihua and Li, Peng and Chen, Yanlin and Fu, Lu and Liu, Huiyi and Ye, Xingdong and Wu, Shulin and Xue, Yumei and Lin, Weidong},
title = {‘Single-shot’ pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad362}
}
EUVIMED