EUVIMEDEUVIMED entdecken
Crossref

Comparison of lesion characteristics using temperature‐flow‐controlled versus conventional power‐controlled ablation with fixed ablation index

Takashi Ikenouchi iD, Masateru Takigawa iD, Masahiko Goya, Claire A Martin iD, Tasuku Yamamoto, Junji Yamaguchi iD, Kentaro Goto, Takatoshi Shigeta, Takuro Nishimura, Susumu Tao, Shinsuke Miyazaki, Tetsuo Sasano iD und 1 weitere

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.15883 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Takashi Ikenouchi und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Steam, Catheter Ablation. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The QDOT‐Micro TM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature‐flow‐controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC‐ablation and conventional power‐controlled (PC)‐ablation.

Methods

A total of 480 RF‐applications were performed on ex‐vivo swine myocardium with predefined AI targets (400/550) or until steam‐pop occurred, using the QDOT‐Micro TM (TFC‐ablation) and Thermocool SmartTouch SF TM (PC‐ablation).

Results

Both TFC‐ablation and PC‐ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm 3 , p = .65); however, lesions using TFC‐ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm 2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC‐alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC‐ablation due to automatic regulation of temperature and irrigation‐flow. Although steam‐pops were less frequent in TFC‐ablation (24% vs. 15%, p = .021), they were particularly observed in low‐CF (10 g) and high‐power ablation (50 W) in both PC‐ablation ( n = 24/240, 10.0%) and TFC‐ablation ( n = 23/240, 9.6%). Multivariate analysis revealed that high‐power, low‐CF, long application time, perpendicular catheter orientation, and PC‐ablation were risk factors for steam‐pops. Furthermore, activation of automatic regulation of temperature and irrigation‐flow was independently associated with high‐CF and long application time while ablation power had no significant relationship.

Conclusions

With a fixed target AI, TFC‐ablation reduced the risk of steam‐pops, producing similar lesions in volume, but with different metrics in this ex‐vivo study. However, lower CF and higher power in fixed‐AI ablation may increase the risk of steam‐pops.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SteamCatheter AblationSwineAnimalsTemperatureTherapeutic IrrigationEquipment Design

Stichwörter der Autor:innen

catheter ablationlesion formationradiofrequencytemperature-flow-controlled ablationtissue

Substanzen

Steam

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan.
  • Department of Cardiology, Royal Papworth Hospital, Cambridge, UK.
  • Department of Clinical and Diagnostic Laboratory Science, Tokyo Medical and Dental University Hospital, Tokyo, Japan.

ORCID-Profile: Takashi Ikenouchi, Masateru Takigawa, Claire A Martin, Junji Yamaguchi, Tetsuo Sasano

Zitieren

APA

Ikenouchi, T., Takigawa, M., Goya, M., Martin, C. A., Yamamoto, T., Yamaguchi, J., Goto, K., Shigeta, T., Nishimura, T., Tao, S., Miyazaki, S., Sasano, T., & Study Group (2023). Comparison of lesion characteristics using temperature‐flow‐controlled versus conventional power‐controlled ablation with fixed ablation index. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15883

Vancouver

Ikenouchi T, Takigawa M, Goya M, Martin CA, Yamamoto T, Yamaguchi J, et al. Comparison of lesion characteristics using temperature‐flow‐controlled versus conventional power‐controlled ablation with fixed ablation index. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15883

BibTeX
@article{Ikenouchi2023,
  author = {Ikenouchi, Takashi and Takigawa, Masateru and Goya, Masahiko and Martin, Claire A and Yamamoto, Tasuku and Yamaguchi, Junji and Goto, Kentaro and Shigeta, Takatoshi and Nishimura, Takuro and Tao, Susumu and Miyazaki, Shinsuke and Sasano, Tetsuo and Study Group, Study Group},
  title = {Comparison of lesion characteristics using temperature‐flow‐controlled versus conventional power‐controlled ablation with fixed ablation index},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.15883}
}
Kostenlos starten →