EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Rationale for and use of the lumenless 3830 pacing lead

Travis D Richardson iD, Adam Himes, Mark Marshall, George H Crossley iD

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.15828 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2023. Verfasst von Travis D Richardson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Pacemaker, Artificial. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Most currently available pacing and defibrillation leads utilize a stylet‐based design that facilitates implantation. This has advantages, but also increases the lead diameter and adds the potential for metal fatigued‐based conductor failure. A systematic literature search was conducted, and the authors add their twenty‐year experience with this lead design. The global experience with lumenless leads was reviewed both for “standard” positioning and with conduction system pacing. Methods for both placement and system modification are reviewed. Lumenless leads have the potential to improve the durability of endocardial pacing and facilitate conduction system pacing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialHumansEquipment DesignCardiac Pacing, ArtificialProsthesis ImplantationCardiac Conduction System Disease

Stichwörter der Autor:innen

catheterslead failurepacemaker leads

Autor:innen und Institutionen

  • Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Medtronic, Inc., Minneapolis, Minnesota, USA.

ORCID-Profile: Travis D Richardson, George H Crossley

Zitieren

APA

Richardson, T. D., Himes, A., Marshall, M., & Crossley, G. H. (2023). Rationale for and use of the lumenless 3830 pacing lead. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15828

Vancouver

Richardson TD, Himes A, Marshall M, Crossley GH. Rationale for and use of the lumenless 3830 pacing lead. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15828

BibTeX
@article{Richardson2023,
  author = {Richardson, Travis D and Himes, Adam and Marshall, Mark and Crossley, George H},
  title = {Rationale for and use of the lumenless 3830 pacing lead},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.15828}
}
Kostenlos starten →