Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing
Heart Rhythm · 2023
DOI: 10.1016/j.hrthm.2023.02.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2023. Verfasst von Pierce J Vatterott und 4 weiteren Autor:innen. Beteiligte Einrichtung: Minneapolis Heart Institute East, Arrhythmia Science Center, Minneapolis, Minnesota. Hauptthemen laut MEDLINE: Pacemaker, Artificial. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medtronic.
Abstract (Originalsprache)
BACKGROUND: With the advent of conduction system pacing, use of the Medtronic SelectSecure Model 3830 lead has increased substantially. However, with this increased use, the potential need for lead extraction also will increase. Lumenless lead construction requires an understanding of both applicable tensile forces as well as lead preparation techniques that can influence consistent extraction. OBJECTIVE: The purpose of this study was to use bench testing methodologies to characterize the physical properties of lumenless leads and to describe related lead preparation methods that support known extraction techniques. METHODS: Multiple 3830 lead preparation techniques, commonly used in extraction practices, were compared on the bench to assess rail strength (RS) in simple traction and use conditions with simulated scar. Retention of the IS1 connector vs severing the lead body preparation techniques were compared. Distal snare and rotational extraction tools were evaluated. RESULTS: The retained connector method provided higher RS compared to the modified cut lead method: mean 11.42 lbf (9.85-12.73 lbf) vs 8.51 lbf (1.66-14.32 lbf), respectively. Snare use distally did not significantly affect RS: mean 11.05 lbf (8.58-13.95 lbf). Lead damage occurred with the TightRail extraction tool at angles ≥90°, which could occur with right-sided implants. CONCLUSIONS: When extracting SelectSecure leads, the retained connector method to maintain cable engagement benefits preservation of the extraction RS. Limiting traction force to
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Minneapolis Heart Institute East, Arrhythmia Science Center, Minneapolis, Minnesota.
- Department of Medicine, Montreal Heart Institute, Montreal, Canada.
- Medtronic, Inc., Cardiac Rhythm Management, Minneapolis, Minnesota.
- Cleveland Clinic, Robert and Suzanne Tomsich Department of Cardiovascular Medicine, Cleveland, Ohio. Electronic address: wilkofb@ccf.org.
Förderung
- Medtronic
Zitieren
APA
Vatterott, P. J., Mondésert, B., Marshall, M., Lulic, T., & Wilkoff, B. L. (2023). Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2023.02.025
Vancouver
Vatterott PJ, Mondésert B, Marshall M, Lulic T, Wilkoff BL. Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing. Heart Rhythm. 2023. doi:10.1016/j.hrthm.2023.02.025
BibTeX
@article{Vatterott2023,
author = {Vatterott, Pierce J and Mondésert, Blandine and Marshall, Mark and Lulic, Thomas and Wilkoff, Bruce L},
title = {Mechanics of lumenless pacing lead strength during extraction procedures based on laboratory bench testing},
journal = {Heart Rhythm},
year = {2023},
doi = {10.1016/j.hrthm.2023.02.025}
}
EUVIMED