EUVIMEDEUVIMED entdecken
Crossref

Structural Optimization Design and Experimental Study of Centrifugal Blood Pump Impeller

Qing Han, Xuemin Liu iD, Jiejie Shao, Peng Wang, Honghua Zhao

Artificial Organs · 2026

DOI: 10.1111/aor.70208 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2026. Verfasst von Qing Han und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, University of Jinan, Jinan, China. Hauptthemen laut MEDLINE: Heart-Assist Devices, Prosthesis Design. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Introducing Urgently Needed Talent in Key Supported Areas of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

As a core component of mechanical circulatory support devices, a centrifugal blood pump with excessively low hydraulic efficiency can lead to poor blood compatibility, low efficiency, excessive heat generation, insufficient blood supply, and pressure fluctuations. These issues adversely affect patient prognosis. To address these bottlenecks, this study aims to perform structural optimization of the centrifugal blood pump with the goal of improving hydraulic efficiency and exploring suitable optimization methods.

Methods

This study takes the UJN‐1 magnetically suspended centrifugal blood pump as the research object, with hydraulic efficiency simulated by computational fluid dynamics (CFD) as the target, and compares the results of optimizing four impeller parameters (blade inlet angle, outlet angle, number of blades, blade height) using orthogonal experiments and neural network‐genetic algorithm (NN‐GA).

Results

Genetic algorithm (GA) optimization yielded an impeller with 20.48° inlet angle, 17.22° outlet angle, 6 blades, and 4.55 mm height. Its hydraulic efficiency increased by 2.38%, outlet pressure fluctuation decreased significantly, and it outperformed the orthogonal pump by 1.57%. Hydraulic experiments validated the results, with deviations within approximately ±1% of CFD.

Conclusion

The NN‐GA demonstrates superior global optimization capabilities to the orthogonal experiment. Significance This study provides new insights for multi‐parameter coupled centrifugal blood pump optimization and guides pump design in energy, chemical, and semiconductor industries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesProsthesis DesignGenetic AlgorithmsHydrodynamicsComputer SimulationHumansNeural Networks, ComputerModels, CardiovascularAlgorithmsEquipment DesignCentrifugation

Stichwörter der Autor:innen

genetic algorithmhydraulic efficiencymagnetically levitated blood pumppressure fluctuationstructural optimization

Autor:innen und Institutionen

  • School of Mechanical Engineering, University of Jinan, Jinan, China.
  • Ningbo Zhongjie Laitong Technology Co., Ltd., Ningbo, China.

ORCID-Profile: Xuemin Liu

Förderung

  • Introducing Urgently Needed Talent in Key Supported Areas of Shandong Province

Zitieren

APA

Han, Q., Liu, X., Shao, J., Wang, P., & Zhao, H. (2026). Structural Optimization Design and Experimental Study of Centrifugal Blood Pump Impeller. Artificial Organs. https://doi.org/10.1111/aor.70208

Vancouver

Han Q, Liu X, Shao J, Wang P, Zhao H. Structural Optimization Design and Experimental Study of Centrifugal Blood Pump Impeller. Artificial Organs. 2026. doi:10.1111/aor.70208

BibTeX
@article{Han2026,
  author = {Han, Qing and Liu, Xuemin and Shao, Jiejie and Wang, Peng and Zhao, Honghua},
  title = {Structural Optimization Design and Experimental Study of Centrifugal Blood Pump Impeller},
  journal = {Artificial Organs},
  year = {2026},
  doi = {10.1111/aor.70208}
}
Kostenlos starten →