Influence of LVAD Cannula Outflow Graft Flow Rate and Location on Fluid-Particle Interactions and Thrombi Distribution: A Primary Numerical Study
Journal of Cardiovascular Translational Research · 2024-12 · 17 (6) · 1316-1327
DOI: 10.1007/s12265-024-10547-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Translational Research, online erschienen am 22.07.2024. Verfasst von Longyan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, China. Hauptthemen laut MEDLINE: Heart-Assist Devices, Models, Cardiovascular, Hemodynamics, Ventricular Function, Left. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Hunan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
A left ventricular assist device (LVAD) supports hemodynamics in heart failure patients. To deepen the understanding of hemodynamic changes and the movement of thrombi in the aorta, we examined three distinct LVAD blood flow rates across two implantation sites using the theory of computational fluid dynamics. Our findings revealed the complex dynamics of blood flow during cardiac systole under various scenarios. We also analyzed thrombi residence time and flow probabilities into aortic branches. Simulation results indicate that thrombi distribution in the aorta is significantly influenced by the location of the LVAD outflow graft and the flow rate. When the LVAD outflow graft is implanted into the ascending aorta, higher flow rates may reduce the risk of cerebral thrombosis. However, lower flow rates may reduce the risk of cerebral thrombosis while it is implanted into the descending aorta. The study may offer valuable insights into the LVAD implantation about the risk of cerebrovascular embolism. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, China.
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China.
- School of Mechanical Engineering and Mechanics, Xiangtan University, Xiangtan, China.
- Department of Cardiology, Xiangya Hospital, Central South University, Changsha, Hunan, China. zhaoyx428@foxmail.com.
- National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China. zhaoyx428@foxmail.com.
ORCID-Profile: Yixia Zhao
Förderung
- Natural Science Foundation of Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Li, L., Shi, L., Tan, X., & Zhao, Y. (2024). Influence of LVAD Cannula Outflow Graft Flow Rate and Location on Fluid-Particle Interactions and Thrombi Distribution: A Primary Numerical Study. Journal of Cardiovascular Translational Research, 17(6), 1316-1327. https://doi.org/10.1007/s12265-024-10547-1
Vancouver
Li L, Shi L, Tan X, Zhao Y. Influence of LVAD Cannula Outflow Graft Flow Rate and Location on Fluid-Particle Interactions and Thrombi Distribution: A Primary Numerical Study. Journal of Cardiovascular Translational Research. 2024;17(6):1316-1327. doi:10.1007/s12265-024-10547-1
BibTeX
@article{Li2024,
author = {Li, Longyan and Shi, Li and Tan, Xiao and Zhao, Yixia},
title = {Influence of LVAD Cannula Outflow Graft Flow Rate and Location on Fluid-Particle Interactions and Thrombi Distribution: A Primary Numerical Study},
journal = {Journal of Cardiovascular Translational Research},
year = {2024},
volume = {17},
number = {6},
pages = {1316--1327},
doi = {10.1007/s12265-024-10547-1}
}
EUVIMED