Marginal and Internal Fit, Surface Roughness and Fracture Resistance of Hybrid Dental Crown Materials Fabricated With Milling and 3D‐Printing Systems: An In Vitro Study

Abdullah M Al-Rifai iD, Ahed Al-Wahadni, Abedelmalek Tabanjah

Australian Dental Journal · 2026

DOI: 10.1111/adj.70052 ↗

At a glance

Journal article in Australian Dental Journal, 2026. Written by Abdullah M Al-Rifai and 2 co-authors. Institution: Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan. Major MEDLINE topics: Crowns, Dental Prosthesis Design, Printing, Three-Dimensional, Dental Marginal Adaptation. 65 references. The full text is freely available in PubMed Central. Funded by: Jordan University of Science and Technology.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

This study evaluated the marginal and internal fit, surface roughness and fracture resistance of three hybrid crown materials fabricated using milling and 3D‐printing.

Methods

A maxillary premolar typodont tooth was prepared and scanned to produce 30 cobalt‐chromium dies through selective laser melting 3D printing. Thirty crowns were fabricated from two milled materials (Vita Enamic; Cerasmart) and one printed material (Irix Max) ( n = 10). Marginal and internal fit were assessed using a three‐dimensional superimposition technique, while surface roughness was measured with an optical profilometer. After cementation, specimens underwent thermocycling for 3600 cycles, followed by 720,000 mechanical loading cycles. Fracture resistance was tested using a universal testing machine and failure modes were recorded. Statistical analysis was performed using one‐way ANOVA test.

Results

No statistically significant differences were observed in marginal fit among the groups. Cerasmart showed significantly higher internal gaps but smoother surfaces than Vita Enamic and Irix Max. Vita Enamic exhibited significantly greater fracture resistance compared to Cerasmart. All failures were catastrophic.

Conclusion

All crowns exhibited comparable marginal fit. Cerasmart demonstrated smoother surfaces but inferior internal adaptation and fracture strength, whereas Vita Enamic provided superior mechanical performance.

Subjects

MeSH terms (MEDLINE)

CrownsDental Prosthesis DesignPrinting, Three-DimensionalDental Marginal AdaptationDental MaterialsSurface PropertiesDental Stress AnalysisDental Restoration FailureMaterials TestingHumansIn Vitro TechniquesChromium Alloys

Author keywords

crownsfracture resistancehybrid materialsmarginal and internal fitsurface roughness

Substances

Dental MaterialsChromium Alloys

Authors and institutions

  • Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan.
  • Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan.

ORCID profiles: Abdullah M Al-Rifai

Funding

  • Jordan University of Science and Technology

Cite

APA

Al-Rifai, A. M., Al-Wahadni, A., & Tabanjah, A. (2026). Marginal and Internal Fit, Surface Roughness and Fracture Resistance of Hybrid Dental Crown Materials Fabricated With Milling and 3D‐Printing Systems: An In Vitro Study. Australian Dental Journal. https://doi.org/10.1111/adj.70052

Vancouver

Al-Rifai AM, Al-Wahadni A, Tabanjah A. Marginal and Internal Fit, Surface Roughness and Fracture Resistance of Hybrid Dental Crown Materials Fabricated With Milling and 3D‐Printing Systems: An In Vitro Study. Australian Dental Journal. 2026. doi:10.1111/adj.70052

BibTeX
@article{AlRifai2026,
  author = {Al-Rifai, Abdullah M and Al-Wahadni, Ahed and Tabanjah, Abedelmalek},
  title = {Marginal and Internal Fit, Surface Roughness and Fracture Resistance of Hybrid Dental Crown Materials Fabricated With Milling and 3D‐Printing Systems: An In Vitro Study},
  journal = {Australian Dental Journal},
  year = {2026},
  doi = {10.1111/adj.70052}
}
Start for free →