Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2024
DOI: 10.1109/tuffc.2024.3420242 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024. Verfasst von Jiro Kusunose und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Phantoms, Imaging, Equipment Design. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH.
Abstract (Originalsprache)
Transcranial-focused ultrasound (tFUS) procedures such as neuromodulation and blood-brain barrier (BBB) opening require precise focus placement within the brain. MRI is currently the most reliable tool for focus localization but can be prohibitive for procedures requiring recurrent therapies. We designed, fabricated, and characterized a patient-specific, 3-D-printed, stereotactic frame for repeated tFUS therapy. The frame is compact, with minimal footprint, can be removed and re-secured between treatments while maintaining sub-mm accuracy, and will allow for precise and repeatable transcranial FUS treatment without the need for MR-guidance following the initial calibration scan. Focus localization and repeatability were assessed via MR-thermometry and MR-acoustic radiation force imaging (ARFI) on an ex vivo skull phantom and in vivo nonhuman primates (NHPs), respectively. Focal localization, registration, steering, and re-steering were accomplished during the initial MRI calibration scan session. Keeping steering coordinates fixed in subsequent therapy and imaging sessions, we found good agreement between steered foci and the intended target, with target registration error (TRE) of 1.2 ± 0.3 ( n = 4 , ex vivo) and 1.0 ± 0.5 ( n = 3 , in vivo) mm. Focus position (steered and non-steered) was consistent, with sub-mm variation in each dimension between studies. Our 3-D-printed, patient-specific stereotactic frame can reliably position and orient the ultrasound transducer for repeated targeting of brain regions using a single MR-based calibration. The compact frame allows for high-precision tFUS to be carried out outside the magnet and could help reduce the cost of tFUS treatments where repeated application of an ultrasound focus is required with high precision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NIBIB NIH HHS
- NIH
Zitieren
APA
Kusunose, J., Rodriguez, W. J., Luo, H., Manuel, T. J., Phipps, M. A., Yang, P. F., Grissom, W. A., Konrad, P. E., Chen, L. M., Dawant, B. M., & Caskey, C. F. (2024). Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2024.3420242
Vancouver
Kusunose J, Rodriguez WJ, Luo H, Manuel TJ, Phipps MA, Yang PF, et al. Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2024. doi:10.1109/tuffc.2024.3420242
BibTeX
@article{Kusunose2024,
author = {Kusunose, Jiro and Rodriguez, William J and Luo, Huiwen and Manuel, Thomas J and Phipps, M Anthony and Yang, Pai-Feng and Grissom, William A and Konrad, Peter E and Chen, Li Min and Dawant, Benoit M and Caskey, Charles F},
title = {Design and Validation of a Patient-Specific Stereotactic Frame for Transcranial Ultrasound Therapy},
journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2024},
doi = {10.1109/tuffc.2024.3420242}
}
EUVIMED