Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding

Qibin Wang, Zhonghao Zhang, Lei Li, Franziska Schrank, Yu Zeng, Pengyue Guo, Harald Radermacher, Volkmar Schulz, Shouping Zhu

IEEE Transactions on Medical Imaging · 2025-04 · 44 (4) · 1878-1889

DOI: 10.1109/tmi.2024.3522979 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-04. Verfasst von Qibin Wang und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Magnetite Nanoparticles. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedMagnetite NanoparticlesPhantoms, ImagingAlgorithmsEquipment Design

Substanzen

Magnetite Nanoparticles

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Wang, Q., Zhang, Z., Li, L., Schrank, F., Zeng, Y., Guo, P., Radermacher, H., Schulz, V., & Zhu, S. (2025). Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding. IEEE Transactions on Medical Imaging, 44(4), 1878-1889. https://doi.org/10.1109/tmi.2024.3522979

Vancouver

Wang Q, Zhang Z, Li L, Schrank F, Zeng Y, Guo P, et al. Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding. IEEE Transactions on Medical Imaging. 2025;44(4):1878-1889. doi:10.1109/tmi.2024.3522979

BibTeX
@article{Wang2025,
  author = {Wang, Qibin and Zhang, Zhonghao and Li, Lei and Schrank, Franziska and Zeng, Yu and Guo, Pengyue and Radermacher, Harald and Schulz, Volkmar and Zhu, Shouping},
  title = {Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2025},
  volume = {44},
  number = {4},
  pages = {1878--1889},
  doi = {10.1109/tmi.2024.3522979}
}
Kostenlos starten →