EUVIMEDEUVIMED entdecken
Crossref

Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique

Siao Lei, Wenxuan Zou, Yanjun Liu, Guanghui Li, Gen Shi, Jiaqian Li, Jie He, Guangxing Zhou, Yang Jing, Yu An, Jie Tian

IEEE Transactions on Medical Imaging · 2026

DOI: 10.1109/tmi.2026.3670844 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2026. Verfasst von Siao Lei und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Magnetic Particle Imaging, Thermography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Beijing Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic Particle Imaging (MPI) enables noninvasive temperature imaging without depth limitations. However, due to the lack of effective calibration strategies that can simultaneously address issues such as calibration infeasibility and environmental mismatch, its practical in vivo application remains challenging. In this work, we propose a novel in vivo temperature imaging method based on a dual-mode magnetic particle spectroscopy/magnetic particle imaging (MPS/MPI) system. First, MPS is employed to capture the differences in harmonic phase responses of magnetic nanoparticles (MNPs) under in vivo and in vitro conditions, thereby enabling the construction of calibration functions that are consistent with the in vivo environment. Second, an MLP based calibration strategy is proposed, which accounts for non-ideal deviations from the approximately linear temperature-phase relationship and integrates multi-parameter information into a unified network, thereby enabling accurate and stable temperature mapping. Comprehensive simulation, in vitro, and in vivo experiments demonstrate that, compared with conventional phantom-based temperature mapping methods, the proposed method reduces the in vivo temperature reconstruction error by approximately 17.24% and achieves an average absolute temperature error below $1.257~^{\circ } $ C. These results verify the feasibility of accurate in vivo temperature imaging using MPI and provide essential technical support for temperature-sensitive applications, including magnetic hyperthermia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Particle ImagingThermographyImage Processing, Computer-AssistedAnimalsPhantoms, ImagingMiceMagnetite NanoparticlesAlgorithmsCalibration

Substanzen

Magnetite Nanoparticles

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Beijing Natural Science Foundation
  • Fundamental Research Funds for the Central Universities
  • Academic Excellence Foundation of Beijing University of Aeronautics and Astronautics (BUAA) Beihang University for Ph.D. Students.

Zitieren

APA

Lei, S., Zou, W., Liu, Y., Li, G., Shi, G., Li, J., He, J., Zhou, G., Jing, Y., An, Y., & Tian, J. (2026). Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2026.3670844

Vancouver

Lei S, Zou W, Liu Y, Li G, Shi G, Li J, et al. Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique. IEEE Transactions on Medical Imaging. 2026. doi:10.1109/tmi.2026.3670844

BibTeX
@article{Lei2026,
  author = {Lei, Siao and Zou, Wenxuan and Liu, Yanjun and Li, Guanghui and Shi, Gen and Li, Jiaqian and He, Jie and Zhou, Guangxing and Jing, Yang and An, Yu and Tian, Jie},
  title = {Phase-Lag-Based MPS/MPI Dual-Mode Precise In Vivo Temperature Imaging Technique},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2026},
  doi = {10.1109/tmi.2026.3670844}
}
Kostenlos starten →