Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging

Jie He, Haoran Zhang, Yimeng Li, Guanghui Li, Siao Lei, Zhumei Qian, Fei Xiong, Yuan Feng, Tao Zhu, Yu An, Jie Tian

IEEE Transactions on Medical Imaging · 2024

DOI: 10.1109/tmi.2024.3404602 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024. Verfasst von Jie He und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Phantoms, Imaging, Image Processing, Computer-Assisted, Signal-To-Noise Ratio. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Guangdong Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Open-sided magnetic particle imaging (OS-MPI) has garnered significant interest due to its potential for interventional applications. However, the system matrix calibration in OS-MPI using sequential scans is a time-consuming task and susceptible to the low signal-to-noise ratio (SNR) resulting from the small calibration sample size. These challenges have hindered the practical implementation of system matrix-based reconstruction for sequentially scanned OS-MPI. To address these issues, we propose a novel calibration method, named sequen- tial scan-based single-dimension multi-voxel calibration (SS-SDMVC), to efficiently obtain a high-SNR system matrix. This method was implemented in a cylindrical field of view (FOV), where a bar calibration sample parallel to the field-free line (FFL) was shifted along a fixed radial direction. A standard image reconstruction process was also introduced to verify the feasibility of SS-SDMVC. Through simulations, we analyzed the effects of noise levels and scanner imperfections on the SS-SDMVC-based reconstruction and demonstrated its robustness. In experiments, we compared the imaging performance of SS-SDMVC and the sequential scan-based traditional cubic-FOV SMC. The results showed that SS-SDMVC reduced the number of measurements by a factor of 210.94 and achieved higher reconstruction quality. Therefore, SS-SDMVC is expected to improve the reconstruction quality of human- scale or high-gradient FFL MPI scanners.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingImage Processing, Computer-AssistedSignal-To-Noise RatioCalibrationAlgorithmsMagnetite Nanoparticles

Substanzen

Magnetite Nanoparticles

Förderung

  • National Natural Science Foundation of China
  • Beijing Natural Science Foundation
  • Guangdong Key Research and Development Program of China

Zitieren

APA

He, J., Zhang, H., Li, Y., Li, G., Lei, S., Qian, Z., Xiong, F., Feng, Y., Zhu, T., An, Y., & Tian, J. (2024). Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3404602

Vancouver

He J, Zhang H, Li Y, Li G, Lei S, Qian Z, et al. Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. 2024. doi:10.1109/tmi.2024.3404602

BibTeX
@article{He2024,
  author = {He, Jie and Zhang, Haoran and Li, Yimeng and Li, Guanghui and Lei, Siao and Qian, Zhumei and Xiong, Fei and Feng, Yuan and Zhu, Tao and An, Yu and Tian, Jie},
  title = {Sequential Scan-Based Single-Dimension Multi-Voxel System Matrix Calibration for Open-Sided Magnetic Particle Imaging},
  journal = {IEEE Transactions on Medical Imaging},
  year = {2024},
  doi = {10.1109/tmi.2024.3404602}
}
Kostenlos starten →