Accurate Concentration Recovery for Quantitative Magnetic Particle Imaging Reconstruction via Nonconvex Regularization
IEEE Transactions on Medical Imaging · 2024-08 · 43 (8) · 2949-2959
DOI: 10.1109/tmi.2024.3383468 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024-08. Verfasst von Tao Zhu und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Algorithms, Image Processing, Computer-Assisted, Phantoms, Imaging. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing Natural Science Foundation, National Natural Science Foundation of China, Chinese Academy of Sciences Youth Innovation Promotion Association.
Abstract (Originalsprache)
Magnetic particle imaging (MPI) uses nonlinear response signals to noninvasively detect magnetic nanoparticles in space, and its quantitative properties hold promise for future precise quantitative treatments. In reconstruction, the system matrix based method necessitates suitable regularization terms, such as Tikhonov or non-negative fused lasso (NFL) regularization, to stabilize the solution. While NFL regularization offers clearer edge information than Tikhonov regularization, it carries a biased estimate of the l1 penalty, leading to an underestimation of the reconstructed concentration and adversely affecting the quantitative properties. In this paper, a new nonconvex regularization method including min-max concave (MC) and total variation (TV) regularization is proposed. This method utilized MC penalty to provide nearly unbiased sparse constraints and adds the TV penalty to provide a uniform intensity distribution of images. By combining the alternating direction multiplication method (ADMM) and the two-step parameter selection method, a more accurate quantitative MPI reconstruction was realized. The performance of the proposed method was verified on the simulation data, the Open-MPI dataset, and measured data from a homemade MPI scanner. The results indicate that the proposed method achieves better image quality while maintaining the quantitative properties, thus overcoming the drawback of intensity underestimation by the NFL method while providing edge information. In particular, for the measured data, the proposed method reduced the relative error in the intensity of the reconstruction results from 28% to 8%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Beijing Natural Science Foundation
- National Natural Science Foundation of China
- Chinese Academy of Sciences Youth Innovation Promotion Association
Zitieren
APA
Zhu, T., Yin, L., He, J., Wei, Z., Yang, X., Tian, J., & Hui, H. (2024). Accurate Concentration Recovery for Quantitative Magnetic Particle Imaging Reconstruction via Nonconvex Regularization. IEEE Transactions on Medical Imaging, 43(8), 2949-2959. https://doi.org/10.1109/tmi.2024.3383468
Vancouver
Zhu T, Yin L, He J, Wei Z, Yang X, Tian J, et al. Accurate Concentration Recovery for Quantitative Magnetic Particle Imaging Reconstruction via Nonconvex Regularization. IEEE Transactions on Medical Imaging. 2024;43(8):2949-2959. doi:10.1109/tmi.2024.3383468
BibTeX
@article{Zhu2024,
author = {Zhu, Tao and Yin, Lin and He, Jie and Wei, Zechen and Yang, Xin and Tian, Jie and Hui, Hui},
title = {Accurate Concentration Recovery for Quantitative Magnetic Particle Imaging Reconstruction via Nonconvex Regularization},
journal = {IEEE Transactions on Medical Imaging},
year = {2024},
volume = {43},
number = {8},
pages = {2949--2959},
doi = {10.1109/tmi.2024.3383468}
}