Correction for X-Ray Scatter and Detector Crosstalk in Dark-Field Radiography
IEEE Transactions on Medical Imaging · 2024
DOI: 10.1109/tmi.2024.3374974 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024. Verfasst von Theresa Urban und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Phantoms, Imaging, Algorithms, Scattering, Radiation, Artifacts. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, Deutsche Forschungsgemeinschaft, Federal Ministry of Education and Research (BMBF) and the Free State of Bavaria through the Excellence Strategy of the Federal Government and the Länder.
Abstract (Originalsprache)
Dark-field radiography, a new X-ray imaging method, has recently been applied to human chest imaging for the first time. It employs conventional X-ray devices in combination with a Talbot-Lau interferometer with a large field of view, providing both attenuation and dark-field radiographs. It is well known that sample scatter creates artifacts in both modalities. Here, we demonstrate that also X-ray scatter generated by the interferometer as well as detector crosstalk create artifacts in the dark-field radiographs, in addition to the expected loss of spatial resolution. We propose deconvolution-based correction methods for the induced artifacts. The kernel for detector crosstalk is measured and fitted to a model, while the kernel for scatter from the analyzer grating is calculated by a Monte-Carlo simulation. To correct for scatter from the sample, we adapt an algorithm used for scatter correction in conventional radiography. We validate the obtained corrections with a water phantom. Finally, we show the impact of detector crosstalk, scatter from the analyzer grating and scatter from the sample and their successful correction on dark-field images of a human thorax.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- European Research Council
- Deutsche Forschungsgemeinschaft
- Federal Ministry of Education and Research (BMBF) and the Free State of Bavaria through the Excellence Strategy of the Federal Government and the Länder
- Technical University of Munich–Institute for Advanced Study
- Philips Medical Systems DMC GmbH
- Karlsruhe Nano Micro Facility
- Helmholtz Research Infrastructure at Karlsruhe Institute of Technology
Zitieren
APA
Urban, T., Noichl, W., Engel, K. J., Koehler, T., & Pfeiffer, F. (2024). Correction for X-Ray Scatter and Detector Crosstalk in Dark-Field Radiography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2024.3374974
Vancouver
Urban T, Noichl W, Engel KJ, Koehler T, Pfeiffer F. Correction for X-Ray Scatter and Detector Crosstalk in Dark-Field Radiography. IEEE Transactions on Medical Imaging. 2024. doi:10.1109/tmi.2024.3374974
BibTeX
@article{Urban2024,
author = {Urban, Theresa and Noichl, Wolfgang and Engel, Klaus Juergen and Koehler, Thomas and Pfeiffer, Franz},
title = {Correction for X-Ray Scatter and Detector Crosstalk in Dark-Field Radiography},
journal = {IEEE Transactions on Medical Imaging},
year = {2024},
doi = {10.1109/tmi.2024.3374974}
}
EUVIMED