EUVIMEDEUVIMED entdecken
Crossref

Steady-State Noncontact Intraocular Pressure Measurement Based on Displacement Gradient

Ruonan Bian, Zimeng Zhou, Honghao Wang, Shengqi Su, Junwen Lu, Xiaohua Lv, Xiuli Liu, Shaoqun Zeng

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4011410-4011410

DOI: 10.1109/tim.2026.3712880 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Ruonan Bian und 7 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Hubei Province Science and Technology Plan Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate measurement of intraocular pressure (IOP) is critical for the diagnosis and management of various ophthalmic diseases. The clinical gold standard, Goldmann applanation tonometer (GAT), delivers high accuracy via steady-state measurement, yet its applanation-based principle renders measurement accuracy susceptible to central corneal thickness (CCT), and carries an inherent infection risk due to corneal contact. Subsequent noncontact tonometers use transient measurement that may introduce larger errors. Here, we show a steady-state, noncontact IOP method based on displacement gradient. This method establishes a steady-state environment with an external pressure loading module and detects corneal apex displacement via optical coherence tomography (OCT). It then fits apex displacement and external pressure with an asymmetric sigmoid function to calculate the gradient and generate the displacement gradient-external pressure correlation curve. The displacement-gradient peak occurs near the pressure-equilibrium state under the tested steady-state loading condition, and the corresponding external pressure is used as the estimated IOP. In ex vivo rabbit cornea experiments over the range of 5–25 mmHg, the proposed method achieved a high measurement accuracy, with a mean error of $- 0.08~\pm ~0.27$ mmHg, supporting its feasibility for IOP estimation. Furthermore, it exhibits a reduced sensitivity to CCT variation. This work validates the feasibility of a steady-state, noncontact IOP measurement strategy and provides a foundation for future in vivo validation.

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Hubei Province Science and Technology Plan Project
  • Postdoctoral Introduction Program of Hubei Province
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Bian, R., Zhou, Z., Wang, H., Su, S., Lu, J., Lv, X., Liu, X., & Zeng, S. (2026). Steady-State Noncontact Intraocular Pressure Measurement Based on Displacement Gradient. IEEE Transactions on Instrumentation and Measurement, 75, 4011410-4011410. https://doi.org/10.1109/tim.2026.3712880

Vancouver

Bian R, Zhou Z, Wang H, Su S, Lu J, Lv X, et al. Steady-State Noncontact Intraocular Pressure Measurement Based on Displacement Gradient. IEEE Transactions on Instrumentation and Measurement. 2026;75:4011410-4011410. doi:10.1109/tim.2026.3712880

BibTeX
@article{Bian2026,
  author = {Bian, Ruonan and Zhou, Zimeng and Wang, Honghao and Su, Shengqi and Lu, Junwen and Lv, Xiaohua and Liu, Xiuli and Zeng, Shaoqun},
  title = {Steady-State Noncontact Intraocular Pressure Measurement Based on Displacement Gradient},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {4011410--4011410},
  doi = {10.1109/tim.2026.3712880}
}